GAM Quick Installation Guide
Positron Access Solutions 17 Document 180-0212-001 R02
You are now ready to securely fasten the cover back onto the enclosure.
Step 10: use a 5 mm Allen (hex) key to secure
the 4 screws to ensure the IP67 water
protection of the enclosure. Tighten the screws
in an X fashion (top-right, bottom-left, top left,
bottom right).
You can now connect the coaxial cable(s) to the F-type COAX connectors of the
unit.
Step 11: remove the protective cap on the F-
type connector(s) where you will attach a
coaxial cable.
Step 12: securely fasten the F-type connector
to the coaxial cable
The final step is the installation of the mounting bracket. The mounting bracket
included with the GAM enclosure facilitates installation on a pole or a flat surface.
You can also strand-mount the device using the optional GAM-STRAND-KIT
adapter.