TROUBLESHOOTING GUIDELINES (continued)
6. Overspeed ywheel
does not turn while hoist
moves ↑UP or ↓DOWN.
a. If you are in the air, push the Overspeed brake test button
and wait to be rescued.
b. If you are on the ground, check and correct the following
as needed:
Obstructions such as dirt or other materials
Wire rope may be worn out. Call your supervisor.
Hoist parts may be worn out. Call your supervisor.
7. Cannot reset the
Overspeed brake reset
knob.
WARNING
DO NOT RESET THE OVERSPEED
UNTIL:
You have determined that there is enough wire rope to
reach a safe landing surface.
You know that the wire rope is not jammed in the hoist.
You know the reason that the overspeed has been tripped
and there is no danger when it is reset.
Power the hoist ↑UP a few inches, at the same time
turning the reset knob counter-clockwise until the reset knob
engages.
8. Hoist does not stop
immediately when the
↓DOWN switch is
released.
Push in the Overspeed brake test button and wait to be rescued.
Call your supervisor.
Return the hoist to be serviced by a Power Climber dealer.