EasyManua.ls Logo

Power Climber ASTRO E1500 - Page 33

Power Climber ASTRO E1500
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 33 of 35 Reference: 708052-1 Issue date: 23-Jul-2014 Revision: B
L. ADJUSTABLE SUSPENDED SCAFFOLD SYSTEMS are to be installed and used in
accordance with the manufacturers recommended procedures.
M. ADJUSTABLE SUSPENDED PLATFORMS MUST NEVER BE OPERATED NEAR LIVE
POWER LINES unless proper precautions are taken. Contact the power service provider for
advice.
N. ALWAYS UTILIZE FALL ARREST EQUIPMENT when working on adjustable suspended
scaffolds or when working near unguarded edges.
O. DO NOT WORK FROM, INSTALL OR MOVE ADJUSTABLE SUSPENDED
SCAFFOLDS if you are sick or impaired in any way.
P. DO NOT WORK ON ADJUSTABLE SUSPENDED SCAFFOLDS when under the inuence
of alcohol or drugs.
Q. DEBRIS SHOULD NOT BE STORED OR ALLOWED TO ACCUMULATE ON A
PLATFORM.
R. INDEPENDENT ADJUSTABLE SUSPENDED SCAFFOLDS ARE TO BE POSITIONED
SO AS TO AVOID OVERLAPPING OR POSSIBLE INTERFERENCE FROM ANOTHER
SCAFFOLD.
II. GUIDELINES FOR ERECTION AND USE OF ADJUSTABLE SUSPENDED SCAFFOLD
SYSTEMS
A. RIGGING:
1. UTILIZE FALL PROTECTION EQUIPMENT when rigging near unguarded edges.
2. SUPPORTING DEVICES must be capable of supporting the hoist rated load with a safety
factor of 4.
3. ALL OVERHEAD RIGGING must be secured from unwanted movement in any direction.
4. COUNTERWEIGHTS USED WITH OUTRIGGER BEAMS must be of a non-owable
material and must be secured to the beam to prevent accidental displacement.
5. OUTRIGGER BEAMS THAT DO NOT USE COUNTERWEIGHTS must be installed
and secured to the roof structure with bolts or other direct connections. Direct connections
shall be evaluated by a competent person.
6. TIE BACK ALL TRANSPORTABLE RIGGING DEVICES. Tieback shall be equivalent
in strength to the suspension ropes.
7. INSTALL TIEBACKS AT RIGHT ANGLES TO THE FACE OF THE BUILDING and
secure them without slack, to a suitable anchor capable of supporting the hoist rated load with
a safety factor of 4.
8. IN THE EVENT THAT TIEBACKS CANNOT BE INSTALLED AT RIGHT ANGLES,
two tiebacks at opposing angles must be used to prevent movement.
9. RIG AND USE HOISTING MACHINES DIRECTLY UNDER THEIR SUSPENSION
POINTS to prevent movement or side loading.