EasyManuals Logo

PowerDrive PD2000 User Manual

PowerDrive PD2000
20 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
The inverter can be used
in
a distance from the battery.
--
POWERDRIVE
model#
Working distance
PD1000 PD1500 PD2000 PD3000
1ft 9AWG 8AWG 6AWG 4AWG
2ft 8AWG 7AWG
SAWG
4AWG
3ft 8AWG 6AWG
SAWG
3AWG
4ft
6AWG
SAWG
3AWG 2AWG
5ft
SAWG
4AWG 2AWG 1AWG
6ft
SAWG
4AWG 2AWG
1/0AWG
7ft 4AWG 3AWG 1AWG 2/0AWG
8ft 4AWG 3AWG 1/0AWG
3/0AWG
9ft
3AWG 2AWG 2/0AWG 3/0AWG
10ft 3AWG 2AWG 2/0AWG 3/0AWG
Error Code
Solution
LUP
Low Battery Voltage. Please charge the car battery
or
replace
1t
with a new one.
OUP
Over VoltaRe Protection. Remove all aRpliances
and turn o the inverter. Check the
ba
ery voltage,
make sure it is within 11-15V.
OCP
Overtemp Protection. Remove all
the
appliances
and turn
off
the inverter. Let
it
cool down for 15
minutes before turning on again.
OPP
OR
Overload protection. Turn off the inverter and
OLP
remove
al
appliances.
U~e
appliance(s) with
smaller power consumption.
Note: The product
is
used
for vehicle
and
powered
by
vehicle battery.