Mounting the
Inverter
Your inverter should not be mounted under the hood of a
vehicle.
If
installing
in
a vehicle, choose a dry, cool, ventilated area as
close
to the battery as practical.
Before
drilling
any mounting holes, make sure that there are no wires, fuel lines,
or tanks directly behind the surface to be
drilled.
To
mount the inverter
1.
Inverter ON/OFF
switch must be
in
the
OFF
position.
2. The inverter should be mounted
horizontally.
3. Position the inverter against the mounting surface and mark locations of the
mounting screw openings.
4.
Remove the inverter and
drill
four
(4)
mounting holes.
5.
Fasten the inverter to the mounting surface using corrosion-resistant fasteners
sized #1
0 or larger.
Connecting the
Inverter
This inverter has two
DC
cable
connections, one positive and one negative. The
order of steps in the
following
procedure minimizes the danger of sparking near
the battery bank.
1.
Prepare
all
cable set ends with ring terminals at
the battery ends.
2.
Install
one fuse holder with fuse on the
Positive
cable
close to the battery
bank end.
3. Make sure the
ON/OFF
switch located on the front panel of the inverter
is
in
the
OFF
(0)
position.
4.
Ensure
all
appliance cords or extension cords are disconnected from
the inverter.
5. Connect a
#8
gauge stranded insulated wire to the enclosure ground terminal
and connect the free end of the wire to the vehicle's chassis or any other
ground point.
6.
Connect the unfused cable to the
Negative(·)
terminal of the battery bank.
7. Connect the
Negative cable to the Inverter's Negative(-)
terminal.
8.
Insulate
the end of cable to be connected to the Positive (
+)
Inverter terminal.
9.
Connect the fused cable
to the battery bank
Positive (
+)
terminal.
1
0.
Connect the
Positive
cable
end to the Positive (
+)
inverter
terminal.
Note:
Sparking
is
normal for the first connection.
1.
Make sure you have good secure
connections-
Do not over-tighten.
2.
If
you need the inf9rmation on the panel
at a distance, you can take out the
control panel and connect
it to
12•
extension cord (included) or simply use