POWX0520 EN
Copyright © 2022 VARO P a g e | 8 www.varo.com
10 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
10.1 Cleaning
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
10.2 Lubrication
From time to time, apply a drop of oil to the thread of the lock screw (18).
11 TECHNICAL DATA
Voltage / frequency
230-240 V / 50 Hz
Power input
1500 W
No load speed
5500 min
-1
Saw blade
Ø 185 x Ø 20 x 2.4 mm
Max. depth of cut 90°
64 mm
Max. depth of cut 45°
48 mm
Mitre angle
0 45°
12 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
104 dB(A)
Acoustic power level LwA
115 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).
aw (Vibration)
2,4 m/s²
K = 1.5 m/s²
13 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).