EasyManua.ls Logo

Powerplus POWX07551T - 13 Troubleshooting; Motor; Saw Operation; 14 Service Department

Powerplus POWX07551T
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
POWX07551T EN
Copyright © 2016 VARO P a g e | 17 www.varo.com
13 TROUBLESHOOTING
13.1 Motor
Cause
Solution
1. Motor brushes not
sealed or lightly sticking
2. Arbor bolt loosened
3. Other
1. Inspect, clean and/or
replace brushes
2. Retighten the arbor bolt
3. Contact customer
service
1. Blown fuse
2. Worn brush
3. Other
1. Use and check the 9A
time-delay fuse or the
circuit breaker
2. See MAINTENANCE
section
3. Contact customer
service
1. Brush worn
1. Replace brushes
13.2 Saw operation
Cause
Solution
1. Misalignment
1. See ASSEMBLY section
1. Mitre table locked
2. Sawdust under table
1. Push positive stop
locking lever down and
rotate table
2. Vacuum or blow out
dust
1. Loose pivot points
1. See ASSEMBLY section
1. Part failure
2. Pivot spring not
replaced properly after
service
3. Sawdust build-up
1. Contact customer
service
2. Contact customer
service
3. See MAINTENANCE
section
1. Improper operation
2. Dull blade
3. Improper blade size
4. Warped blade
1. See OPERATIONS
section
2. Replace or sharpen
blade
3. Replace blade
4. Replace blade
1. Saw blade not round
2. Saw blade damaged
3. Saw blade loose
4. Saw blade warped
1. Replace blade
2. Replace blade
3. Tighten arbor bolt
4. Replace blade
14 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).

Table of Contents