FOR RESIDENTIAL
USER MANUAL
PC170 Control Box
24V DC GEAR MOTOR

Questions and Answers

  • H
    hayeswilliamAug 17, 2025
    What to do if the PowerTech PC170 Control Panel gate doesn’t move when pressing the transmitter button?
    • S
      Scott FergusonAug 17, 2025
      If your PowerTech Control Panel gate doesn’t move when you press the transmitter button, try the following: 1. Check if LED3 or 4 is on. 2. Verify the batteries' voltage is above 22V. 3. Check if LED1 is on. 4. Ensure all wiring connections are firmly connected to the terminals on the PCB. 5. Check the fuse to ensure it is working.
  • C
    Christina StephensAug 19, 2025
    What to do if the leaves suddenly stop during moving on my PowerTech PC170?
    • A
      Abigail WeberAug 19, 2025
      If the leaves suddenly stop during moving when using your PowerTech Control Panel, consider the following: 1. Check if the “RESET” socket is activated. 2. Ensure the wiring connection of the gear motors is firm. 3. Ensure the hall sensor wiring connection is firm. 4. If no photocells are installed, the GND terminal of the photocells on the PCB must be short-circuited. 5. Make sure the fuse is workable.
  • A
    anne86Aug 22, 2025
    What to do if the leaves does not move or only move toward one direction on my PowerTech PC170 Control Panel?
    • A
      andrewcopelandAug 22, 2025
      If the leaves on your PowerTech Control Panel either don't move or only move in one direction, here's what you should check: 1. See if the “RESET” socket is activated. 2. Make sure the wiring connection of the gear motors is firm. 3. Confirm the hall sensor wiring connection is secure. 4. If you haven't installed photocells, be sure the GND terminal of the photocells on the PCB is short-circuited.
  • D
    Douglas BarrettAug 25, 2025
    What to do if the gear motors does not run and the relay is noisy on PowerTech PC170 Control Panel?
    • C
      Chelsey AllenAug 26, 2025
      If the gear motors on your PowerTech Control Panel don't run and the relay is noisy when you try to open or close the gate, the first thing to check is whether the fuse is burned.
  • J
    James KingAug 28, 2025
    Why is the transmitting distance too short on my PowerTech Control Panel?
    • S
      Sara MaloneAug 28, 2025
      If the transmitting distance of your PowerTech Control Panel is too short, ensure the connecting terminals of the Antenna are firmly connected.
  • S
    scottcourtneyAug 30, 2025
    What to do if the gate only moves a little distance on PowerTech PC170?
    • A
      Ashley PenaAug 30, 2025
      If the gate only moves a little distance when you press the transmitter button on your PowerTech Control Panel, make sure the wiring connection of the hall sensor is firm.
  • M
    Mary MaddenSep 2, 2025
    How to fix overheated back-up batteries in PowerTech Control Panel?
    • D
      danielle50Sep 2, 2025
      If the back-up batteries are overheated in your PowerTech Control Panel, check the wiring connection of the batteries.
  • P
    pwatsonSep 5, 2025
    What to do if the flashing light does not work on PowerTech Control Panel?
    • C
      Christina MatthewsSep 5, 2025
      If the flashing light on your PowerTech Control Panel isn't working, check if the wiring connection of the flashing light is correct.
  • R
    rileylopezSep 7, 2025
    Why do the gear motors run very slowly on my PowerTech Control Panel?
    • J
      Jay KleinSep 8, 2025
      If the gear motors on your PowerTech Control Panel run very slowly, check the dip switch setting of the speed adjustment.
  • R
    Robert MoraSep 12, 2025
    What to do if the leaves shall be closed instead of opening on PowerTech PC170 Control Panel?
    • C
      Colleen GrahamSep 12, 2025
      If the leaves close instead of opening on your PowerTech Control Panel, change the polarity connection of the positive (+) with the negative (-) of the gear motors.

Summary

Control Box Installation and Wiring

Control Box Installation Steps

Details the steps for installing the control box, including mounting and wiring connections for accessories and motors.

Photocell Wiring Configuration

Configures SW3 settings for photocell connections, detailing options for one or two sets and no photocells.

System Settings and DIP Switches

SW1 DIP Switch Settings

Configures gate motor behavior like slowdown, over-current, and auto-close using SW1 DIP switches.

SW2 DIP Switch Settings

Adjusts safety features and gate operation modes using SW2 DIP switches.

Gate Auto-Close Adjustment

Configures automatic gate closing delay times based on SW1 DIP switch combinations.

Advanced DIP Switch Functions

Pedestrian and Flashing Light Adjustment

Configures pedestrian mode and flashing light behavior using SW1 DIP switches.

Photocell Adjustment (SW2)

Configures photocell behavior for gate safety and operation based on SW2 DIP settings.

Gate Operation and Transmitter Settings

Gate Operation Logic

Explains how gates respond to transmitter, push button, or key selector commands and safety features.

Advanced Transmitter Operation

Details advanced transmitter functions and button assignments based on SW3 DIP settings.

Troubleshooting Common Issues

Gate Movement and Transmitter Problems

Addresses issues like gates not moving, short transmitting distance, or slow motor operation.

Motor and Sensor Faults

Diagnoses problems with sudden stops, one-directional movement, or noisy motors and relays.

Photocell Installation Guide

Photocell Specifications

Provides technical details for the safety photocells, including detection method, range, and voltage.

Photocell Wiring and Connection

Details the wiring connections for the photocell transmitter (TX) and receiver (RX) to the control board.

PowerTech PC170 Specifications

General IconGeneral
Resolution800 x 480 pixels
Mounting TypePanel Mount
Storage Temperature-20°C to 60°C
Display TypeLCD
Screen Size7 inches