2.6 GATE OPERATION
Press the button “A” on the transmitter for dual-gate operation.
Press the button “B” on the transmitter for single-gate
operation in either single-gate or dual-gate installation.
2.7 GATE-MOVING LOGIC
(A) In gate-opening phase: The gates stop if the transmitter/push button/key selector is activated, and close when
the transmitter/push button/key selector is reactivated.
(B) In gate-closing phase: The gates stop if the transmitter/push button/key selector is activated, and open when
the transmitter/push button/key selector is reactivated.
(C) In gate-opening or gate-closing phase: For safety purpose, the gates stop if encountering obstacles.
2.8 ADVANCED OPERATION OF THE TRANSMITTER (SW3 DIP1/2 REMOTE 1 & REMOTE2)
A.PR-1/PR-2
Situation 1: Dip1. Remote 1:ON & Dip2. Remote 2:ON
Transmitter button A for single leaf operation.
Transmitter button B for double leaves operation.
Situation 2: Dip1. Remote 1:ON & Dip2. Remote 2:OFF
Transmitter button B for single leaf operation.
Transmitter button A for double leaves operation.
B.PR-2 Extensive (Optional)
Situation 3: Dip1. Remote 1:OFF & Dip2. Remote 2:ON
Transmitter button C for single leaf operation.
Transmitter button D for double leaves operation.
Situation 4: Dip1. Remote 1:OFF & Dip2. Remote 2:OFF
Transmitter button D for single leaf operation.
Transmitter button C for double leaves operation.
See the following description:
SW3
OFF ON
A
C
D
B
PR-2
CONTROL BOX
7
A
B