12
9 TECHNICAL SPECIFICATIONS
Max open voltage of PV module
Max. Input Power:
For 12V system
For 24V system
User default, Sealed, Flooded, GEL, LiFeP04
Equalized charging voltage
Maintenance-fee lead acid battery: 14.6V;
GEL: No; Lead acid flooded battery: 14.8
Absorption charging voltage
Maintenance-fee lead acid battery: 14.4V;
GEL: 14.2; Lead acid flooded battery: 14.6
Floating charging voltage
Maintenance-fee lead acid battery,
GEL, Lead acid flooded battery: 13.8
Low voltage re-connection
(LVR)
Maintenance-fee lead acid battery,
GEL, Lead acid flooded battery: 12.6
Low voltage disconnection
(LVD)
Maintenance-fee lead acid battery,
GEL, Lead acid flooded battery: 10.8
High voltage disconnection
(HVD)
Duration Of absorption charging
-20℃~+55℃(To run at full rated current continuously)
Installation hole size(LxW)mm