6. Maintenance
UP! mini 3D Printer User Manual 48
6.2 Vertical Calibration
The vertical calibration procedure is to ensure that the print platform of UP!
printer is level and that printer prints consistently in the X, Y and Z axes.
First, UP! Software provides a calibration model located in the directory
"Example". Print the calibration model on your printer.
Figure 6-1 Calibration Model
After the calibration model is printed, measure the X1 and X2 length, as shown
in Figure 6-2.
Figure 6-1 Measure X1 and X2
Open the “Calibrate” box from the “3D Print” menu and enter the measured X1
and X2 values into the appropriate boxes.