EasyManua.ls Logo

PPS PPS25 - 4.3 Inspecting Gauges

PPS PPS25
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PPS25 Electronic Memory Gauge
User Manual
Pioneer Petrotech Services Inc.
infopps@pioneerps.com
1-888-PP-GAUGE (774-2843)
www.pioneerps.com
4.3 Inspecting Gauges
PPS SmartView software can be used to test the gauges before a filed operation.
Please refer to “PPS SmartView User Manual” for more detail.
Procedure:
(1) Complete a bench test by plugging in a battery pack for 10mins;
(2) Connect a PPS USB download interface to the gauge (Fig. 1) and a computer to download
data and check if the record data is normal;
(3) Run SmartView and use “Diagnostics” in Options Tab to test the gauge (Fig. 2).
Click “Start” Button
Fig. 2
To ensure gauges are functional, a regular inspection (Bench Test) is
necessary before each operation.
Fig. 1
Your gauges may have a different receptacle (4pin or 6pin), please make sure
you are using a proper plug on the USB interface for connection.
The pressure and temperature reading should be reasonable at atmospheric
pressure and ambient temperature.