5715V102-UK 9
Electrical specifications
Specifications range:
-20°C to +60°C
Common specifications:
Supply voltage, universal ............................ 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Consumption:
Isolation voltage, test / operation ............... 2.3 kVAC / 250 VAC
Signal / noise ratio ...................................... Min. 60 dB (0...100 kHz)
Communications interface .......................... USB Loop Link
Response time (0...90%, 100...10%):
Temperature input .................................... < 1 s
Current / voltage input ............................. < 400 ms
Calibration temperature............................... 20...28°C
Accuracy, the greater of general and basic values:
General values
Input type
Absolute
accucary
Temperature
coefficient
All ≤ ±0.1% of reading ≤ ±0.01% of reading / °C
Type Internal consumption Max. consumption
5715B 3.0 W 3.3 W
5715D 3.5 W 3.8 W
Type Version
5715 4 relays ....................: B
Analogue output and 4 relays ..: D
Order: 5715