Alwaysconnecttheconverterwheninstallationiscompleteandaftercheckingall
thecablings.
Groundconnections
To avoid corrosion of the TCO layer and consequently a permanent failure of the photovoltaic
module,thenegativeterminalshouldbegrounded.Inviewoftheabove,itismandatorytoinstall
aninverterwithgalvanicisolationtoensuresafety.
NOTE
MCPHPV modules are compatible and must beconnected only to inverters with
transformerincluded.
DANGER
Make all connections according to local regulation for compliance and safety of
electricalinstallations.
Instructionsforsystemshut‐down
1. Before disconnecting the modules through the Multi‐Contact cables, we recommend
interrupting the production of electrical energy. To interrupt the production of electrical
energy,coverthemodulescompletelyusinganopaque,non‐inflammablematerialorwait
fornight‐timeconditions(nodaylight).
2. Disconnectmodulesfromothersourcesofelectricity,
suchasbatteriesorinverters,when
workingonthesystem.