EasyManua.ls Logo

Precision Medical Live Active Five - Device Overview; About the Live Active Five POC; Intended Use, Indications, and User Profile; Contraindications and Safety Precautions

Precision Medical Live Active Five
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
Device Overview
About Your Live Active Five Portable Oxygen Concentrator (POC)
The Live Active Five POC uses a molecular sieve and vacuum pressure swing adsorption
methodology to produce the oxygen gas output. Ambient air enters the device, is filtered
and then compressed. This compressed air is then directed into nitrogen adsorbing sieve
beds. Concentrated oxygen exits the opposite end of the sieve bed and is directed into
an oxygen reservoir from which it is delivered to the user.
The oxygen purity level of the output gas ranges from 87% to 95.5%. The oxygen is
delivered to the user through the use of a nasal cannula. A pulse dose delivery method
is used. The device detects the start of user inhalation and delivers a measured pulse
of oxygen. No further oxygen is delivered until the next user inhalation is detected. The
volume of oxygen delivered each minute is a fixed amount based on the selected pulse
flow setting. The volume of each oxygen pulse will vary with the user’s breath rate such
that the fixed minute volume is maintained.
Intended Use and Indications
The Precision Medical Inc. Live Active Five (POC) (the device) is intended to provide
supplemental oxygen to persons requiring oxygen therapy. The device can be used in
home, institution, vehicle and for transportable use.
User Profile
The Live Active Five POC is to be used by a trained patient and/or caregiver in or outside
the home that requires prescribed supplemental oxygen.
The user should have a visual acuity of 0 on the log Minimum Angle of Resolution (log
MAR) scale or 6/6 (20/20), corrected if necessary.
The user should not have a hearing impairment that would prevent them from hearing
the device alerts.
The user must be able to read and understand the supplied user manual in the language
it is written.
Contraindications
This device is not intended to use while sleeping.
This device is not to be used for support or to sustain life.
This device is intended to provide supplemental oxygen only. An alternate source of
oxygen shall always be available.
This device is not intended for newborn and infant use.
This device is not appropriate for any user who would experience adverse health
consequences as a result of a temporary interruption in oxygen therapy.
This device should only be used when prescribed by a physician. The use of non-
prescribed oxygen therapy can be hazardous.
Users who are unable to communicate discomfort while using this device may require
additional monitoring.
Users with hearing and/or sight impairment(s) may need assistance while using this device.
Users who breathe from their mouths or through an oxygen mask should not use this device.

Table of Contents