Procedure 6.6- Replacing the Circuit Breaker
1. Set the treadmill circuit breaker in the “off” position and unplug the treadmill’s line cord from
the A.C. outlet.
2. Remove the treadmill’s motor cover.
3. Remove the four screws that fasten the mounting panel to the treadmill.
Diagram 6.5 - Treadmill Dress Panel (Rear View)
4. Note where both brown wires, the yellow wire and the violet wire are connected to the
circuit. Disconnect all four wires from the circuit breaker.
5. Lift the mounting panel from the treadmill frame to access the bottom side of the mounting
panel.
6. Note the orientation of the circuit breaker in the dress panel. The replacement circuit breaker
must be mounted in the same orientation. Remove the circuit breaker mounting screws.
Remove the circuit breaker from the treadmill.
7. Set the replacement circuit breaker in the “OFF” position, to prevent the treadmill from
starting immediately when the line cord is inserted in the wall A.C. outlet. Fasten the circuit
breaker to the mounting panel using the screws removed in step 6.
8. Connect the two brown, yellow and violet wires as noted in step 4.
9. Set the mounting panel in its mounting position, fasten it with the screws removed in step 3.
10. Replace the treadmill’s motor cover. Check treadmill operation per Section 3.
A.C. Input
Module
Circuit Breaker
Line Filter
Mounting
Screw
Mounting
Screw
Mounting
Panel