Page 21
For technical questions, please call 1-888-866-5797.
70476
SAFETYOPERATIONMAINTENANCE SETUP
Reprogramming the Start/Stop Remote Control
If the Start/Stop Remote Control is
replaced or needs to be paired to the
generator, follow this procedure:
1. Push the Engine/Battery Switch
to the RUN (ON) position.
2. Push and hold the Engine Start /
Stop Switch for 10 seconds until
the Switch Indicator Light flashes
green, then release the Switch.
3. Push the 2x button on the Stop/Start Remote
Control. It will pair with Generator and the Switch
Indicator Light on the Generator will stop flashing.
Fuel Selector Switch
Turn the Fuel Selector Switch on the Control
Panel to the desired fuel setting.
Note: The Engine is equipped with a safety solenoid
valve — Battery must be connected and charged
to allow operation with LPG or NG fuel.
1. To operate the Generator on gasoline turn the
Fuel Selector Switch to the GAS setting.
2. To operate the Generator on LPG / Propane turn the
Fuel Selector Switch to the PROPANE setting.
3. To operate the Generator on Natural Gas turn
the Fuel Selector Switch to the NG setting.
4. When the Generator is not in use turn the
Fuel Selector Switch to the OFF/ STORAGE
position to turn off all fuel flow to Engine.
OFF/ST OR AGE
GA SOLINE
PR OPANE
NG
Engine / Battery
Switch
Engine Stop / Start
Switch
2x
OFF
Remote Control
Activation Light
OFF Button
ON (2x) Button
PR OPANE
NG
OFF/STORAGE