Page 27
For technical questions, please call 1-888-866-5797.
70476
SAFETYOPERATIONMAINTENANCE SETUP
Stopping the Engine
To stop the Engine in an emergency,
push the Engine / Battery Switch to STOP.
NOTICE: Generator shutoff under
load may damage the Generator
and attached equipment.
Under normal conditions, use the following procedure to shut off the Generator:
1. Turn all electrical load
devices off and unplug them
from the Generator.
2. Slowly press and release the
Engine Start/Stop Switch. Or
slowly press and release the OFF
button on the Stop / Start Remote
Control. Turn the Fuel Selector
Switch to the STORAGE position.
Note: When the Generator is turned
OFF using the Stop / Start Switch or
Remote Control, the Generator enters
standby mode and can be restarted
remotely using procedures indicated in
starting section. If Generator is not
started within 12 hours the Controller
shuts down completely to save the
battery. Push the Engine / Battery
Switch to STOP then RUN to reactivate
standby mode.
3. Push the Engine / Battery
Switch to the STOP position.
Note: Turn the Engine/Battery Switch
off when the Generator is not in
use to prevent draining the Battery.
4. If operating on LPG / Propane, turn
the propane tank valve to the fully
closed position.
5. If operating on Natural Gas,
turn the NG shutoff valve
to the closed position.
EMERGENCY
SHUT OFF
1
2
2x
OFF
3
4 5
Close