7
AUGER SYSTEM DRIVE UNIT SPECIFICATIONS
The PREMIER Driver-Breaker with an attached auger system currently has 3 available model options for the auger drive
unit. Listed below are the specifications for these drive units.
MS11
MS14
MS18
Max. Auger
Diameter
( in )
24
30
36
Min. Hydraulic
Flow
( gal/min )
6
10
15
Max. Hydraulic
Flow
( gal/min )
12
20
30
Max. Hydraulic
Pressure
( psi )
3500
3500
3500
Output Shaft
Size
( in )
2-9/16” Round
OR
2” Hex
2-9/16” Round
OR
2” Hex
2-9/16” Round
OR
2” Hex
Output Speed
GPM
RPM
GPM
RPM
GPM
RMP
7
45
12
50
15
50
9
58
15
61
18
60
11
71
17
71
20
67
-
-
20
83
25
83
Output Torque
PSI
FT LBS
PSI
FT LBS
PSI
FT LBS
2500
1274
2500
1825
2500
2290
3000
1529
3000
2190
3000
2748
3500
1783
3500
2555
3500
3206
*Output speed and output torque specifications are based on theoretical values and are provided for comparative purposes