STORAGE
For long-term storage:
1. Empty the water tank and leave both the
continuous and bottom drainage caps
and drainage plugs o and unplugged.
2. Run the appliance in fan-only mode on
the low fan speed setting for 12 hours to
allow the interior of the appliance to fully
dry.
3. Turn o the appliance, replace both the
continuous and bottom drainage caps
and drainage plugs, and unplug the power
cord.
4. Remove the heat exhaust hose.
5. Remove the batteries from the remote
control.
6. Ensure the appliance and water tank are
clean and dry before storage.
7. Do not kink or wrap the power cord and
plug around the appliance, as this may
cause the insulation to weaken or split,
particularly where it enters the appliance.
8. Cover the appliance and all accessories
with a waterproof covering and store
in a safe, dry place, out of the reach of
children.
SAFETY FEATURES
Anti-Frost Protection
If the internal pipe temperature drops too
low the unit will pause. The display will show
E4 and the appliance will initiate anti- frost
protection rendering the control panel buttons
inactive, apart from the power button. Once
the internal pipe temperature has warmed to
above 8°C (46.4°F) the anti-frost protection
will cease and the appliance will return to
operating at the chosen settings.
Compressor Delay Protection
To protect the compressor, apart from when
the appliance and compressor are activated
for the rst time after being turned on via the
power button, there will be a three minute
delay between every occurrence of the
compressor turning o and on.