Function
Description
Setting
options
Factory
setting
SELF
LOCK
MOD1:
Automatic
operation
MOD1-
MOD3
MOD1
MOD2:
Manual
operation
for
OPEN
and
CLOSE
MOD3
:
Manual
operation
for
CLOSE
SUIWI
Connection
to
terminal
strip
X4
(9
+ 1
O)
MOD1-
MOD7
MODS
MOD1:
(SUIWI
button
1)
When
the
button
is
pressed,
the
door
opens
as
far
as
the
intermediate
position
PART
OPEN.
There
is
no
automatic
closing
of
the
door
from
the
position
PART
OPEN.
MOD2:
(SU/WI
se
lectar
switch
1)
Closed:
all
OPEN
commands
lead
to
the
position
PART
OPEN.
Open:
all
OPEN
commands
lead
to
the
position
OPEN.
The
door
closes
automatically
from
both
positions
.
MOD3:
(SUIWI
se
lectar
switch
2)
Closed:
all
OPEN
commands
lead
to
the
position
PART
OPEN.
Open
:
all
OPEN
commands
lead
to
the
position
OPEN
.
The
door
closes
automatically
only
from
the
position
PART
OPEN.
MOD4:
(SUIWI
selector
switch
3)
Closed
:
all
OPEN
commands
lead
to
the
position
PART
OPEN
.
Open:
all
OPEN
commands
lead
to
the
position
OPEN.
The
door
closes
automatically
only
from
the
position
OPEN.
MODS:
(S
UIWI
button
2)
When
the
button
is
pressed,
the
door
opens
as
far
as
the
intermediate
position
PART
OPEN.
Automatic
closing
of
the
door
also
occurs
from
the
position
PART
OPEN
.
MOD6:
Activation
of
automatic
closing
Closed:
no
auto
matic
closing
of
the
door
Open
:
automatic
closing
of
the
door
is
acti
ve
MOD?:
External
input
for
clock
The
door
opens
ance
the
contact
closes
and
remains
in
the
position
OPEN
until
the
contact
opens.
The
door
then
closes
automatically.
This
function
can
be
aborted
by
pressing
the
CL
OSE
button.
The
door
then
closes.
P/E
BARRIER
MOD1:
Stop
when
activated
MOD
1
MOD
2
CLOSED
MOD2:
Stop
and
reverse
when
activated
MOD
2
P/E
BARRIER
MOD1:
Photoelectric
barrier
not
active
MOD
1
MOD1
OPEN
MOD2:
When
the
photoelectric
barrier
is
activated
between
the
CLOSED
end
MOD
2
position
and
the
pre-limit
switch
CLOSE,
the
door
stops.
The
red
light
is
on.
The
pre
-
limit
switch
CLOSE
goes
automatically
to
CLOSED
end
position
+
600.
SEP
MOD1:
No
function
MOD1
MOD1
LEADING
MOD2:
Leading
photoelectric
barrier
(MFZ)
MOD
2
MAX
SPEED
Sets
the
frequency
that
regulates
the
speed
for
the
OPEN
door
run.
10Hz-100Hz
SO
Hz
OPEN
-
Maximum
speed
of
the
drive
for
the
OPEN
door
run
MIN
SPEED
Sets
the
frequency
that
regulates
the
speed
for
the
OPEN
door
run
.
10H
z-
SO
Hz
25Hz
OPEN
-
Minimum
speed
of
the
drive
for
the
OPEN
door
run
(creep
s
peed)
MAX
SPE
ED
Sets
the
frequency
that
regulates
the
speed
for
the
CLOSE
door
run.
10Hz
-
100H
z
SO
Hz
CL
OSE
-
Maximum
speed
of
the
drive
for
the
CL
OSE
door
run
MIN
SPEED
Sets
the
frequency
that
regulates
the
speed
for
the
CLOSE
door
run.
10Hz
-
50Hz
25Hz
CL
OSE
-
Minimum
speed
of
the
drive
for
the
CLOSE
door
run
(creep
speed)
SPEED
UP
Acceleration
time
from
minimum
speed
to
maximum
speed
.
O,
1 Sec.- 2
Sec.
1,0
Sec.
f ' ·
..
j
-:.