3
Ω, kΩ, MΩ Ohm, Kilohm, Megohm (resistance)
Ampere (current)
Temperature ℃ or ℉
mF, μF, nF Farad - The unit of capacitance.
Millifarad - 1x10-3 or 0.001 farad.
Microfarad - 1x10-6 or 0.000001 farad.
nF - 1x10-9 or 0.000000001 farad.
3. Specifications
The meter should specify one year as a cycle to re-calibrate in the conditions of 18℃ ~ 28
℃ and relative humidity less than 75%.
3.1 Overview
Automatically select measurement function and range.
Overload protection for the whole measurement range.
Maximum allowable voltage between the measuring terminal and the Earth: 600V DC or
600V AC
Work height: Maximum 2000m
Display: LCD
Maximum display value: 4000 digits.
Max open jaw: 30mm.
Polar indication: Automatically indicate,‘-’ means negative polarity.
Over range Indication: ‘0.L’ or ‘-0.L’.
Sampling time: About 3 times/s
Automatic power off time: 15 minutes
Power supply: 1.5V AAA battery ×2
Battery low voltage indication: LCD display symbol.
Temperature coefficient: < 0.1×Accuracy/℃
Working temperature: 18℃ ~ 28℃
Storage temperature: -10℃ ~ 50℃