Start the engine as described above and
allow it to idle for approx. 3 minutes.
Check the engine runs smoothly and that
there are no abnormal sounds or vibrations.
Stop the engine and have it checked by an
authorised workshop if anything abnormal
Connect a heavy-duty cable between the
generator’s earth terminal (9) and an external
Connect the devices to be powered to the
Set the switches (6, 8) for the power outlets
to the ON position. Switch on the connected
devices one at a time, never simultaneously.
Start the device that uses most power fi rst.
Never use fl oodlights with other types of
If a device is defective, runs too slowly or
suddenly stops when connected to the
generator, switch it off immediately. Check
the connected device for defects.
NB! Stay within the rated power limit of the
generator as far as possible.
If the generator’s 12 V outlet is overloaded,
the circuit breaker will trigger and switch off
the generator. Switch off the engine, turn off
one or more of the connected appliances
and press the reset button (6). Restart the
generator and continue with a lower load.
The generator must not operate at maximum
output for more than 30 minutes!
If the generator is not to be used for a
period longer than 2 months, the following
procedure must be performed before putting
Empty the carburettor by loosening the
screw (A) and draining the petrol into a
Clean the outside of the generator.
Remove the spark plug, and pour a few drops
of new engine oil into the hole by the spark
plug. Replace the spark plug, but do not
replace the spark plug cover.
Pull the starter handle so the engine turns
Pull the starter handle slowly until you feel
Store in a dry, well-ventilated place.
Always switch off the engine and allow the
generator to cool before undertaking any
Clean by wiping all surfaces with a damp
Regularly lubricate all moving parts with
lubricating oil and check for rust formation.