VENT-FREE GAS
FIREPLACE INSERT
OWNER’S OPERATION AND
INSTALLATION MANUAL
MODEL FBD28T
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-866-573-0674, 8:00 am - 4:15 pm CST,
Monday through Friday or email customerservice@usaprocom.com
PFS
®
US
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
WARNING: This appliance is equipped for Natural and
Propane gas. Field conversion is not permitted other than
between natural or propane gases.

Other manuals for Procom FBD28T

Questions and Answers

  • P
    Phillip LopezSep 23, 2025
    Why is there a high yellow flame during burner combustion in my Procom FBD28T?
    • T
      Tiffany GuzmanSep 23, 2025
      If you notice a high yellow flame during burner combustion in your Procom Indoor Fireplace, it could be due to insufficient air supply. Check the burner for dirt and debris, and clean it if necessary. Alternatively, the gas regulator may be defective, requiring replacement. Also, the inlet gas pressure could be too low, so you should contact your local gas supplier.
  • D
    Devon HarveyAug 25, 2025
    Why do I smell gas when Procom FBD28T Indoor Fireplace is off?
    • S
      Sara ScottAug 25, 2025
      If you smell gas even when your Procom Indoor Fireplace control knob is in the OFF position, it indicates a gas leak. You should locate and correct all leaks.
  • C
    Charles BrownAug 25, 2025
    What to do if my Procom Indoor Fireplace shuts off while in use?
    • N
      Natalie GreenAug 26, 2025
      If your Procom Indoor Fireplace heater shuts off during use, with the ODS operating, try opening a window or door for ventilation. If that doesn't work, contact your local gas supplier or clean the ODS/pilot.
  • M
    matthewstephensAug 26, 2025
    Why is the flame high and yellow on my Procom FBD28T?
    • F
      fmccormickAug 27, 2025
      If you see a high yellow flame during burner combustion in your Procom Indoor Fireplace, check the burner for dirt and debris and clean it if necessary. If the problem persists, replace the gas regulator or contact your gas supplier.
  • C
    Carmen FosterSep 23, 2025
    Why is there slight smoke or odor during initial operation of my Procom FBD28T?
    • A
      Anthony ShieldsSep 23, 2025
      The slight smoke or odor during the initial operation of your Procom Indoor Fireplace is likely due to residues from the manufacturing process. This issue should resolve itself after a few hours of operation.
  • K
    kirbydawnSep 13, 2025
    Why is there a gas odor during combustion in my Procom FBD28T?
    • C
      catherine47Sep 13, 2025
      If you notice a gas odor during combustion in your Procom Indoor Fireplace, there might be foreign matter between the control valve and burner; disassemble the gas tubing to remove any obstructions. Additionally, there could be a gas leak. You should locate and correct all leaks.
  • M
    Marissa KruegerSep 12, 2025
    What to do if burner(s) does not light after ODS/pilot is lit in Procom FBD28T?
    • N
      Nichole WrightSep 12, 2025
      If your Procom Indoor Fireplace burner(s) does not light after the ODS/pilot is lit, it could be due to a clogged burner orifice. Try cleaning the burner orifice or replacing it. Also, the burner orifice diameter might be too small, in which case you should replace it. Finally, the inlet gas pressure could be too low, so you should contact your local gas supplier.
  • K
    kingerinSep 12, 2025
    Why does the flame go out when I release the control knob on my Procom Indoor Fireplace?
    • J
      jason07Sep 12, 2025
      If the ODS/pilot lights but the flame goes out when you release the control knob on your Procom Indoor Fireplace, ensure the control knob is fully pressed in and held for at least 30 seconds after the pilot lights. Also, make sure the equipment shutoff valve is fully open. Check the thermocouple connection at the control valve and hand tighten it until snug, then tighten it an additional 1/4 turn. If the pilot flame isn't touching the thermocouple, contact your local gas company, or clean/replace the ODS/pilot assembly. If the thermocouple is damaged, replace it.
  • P
    Pedro WilliamsSep 4, 2025
    Why is there condensation on my windows when using Procom FBD28T?
    • T
      Timothy HansonSep 4, 2025
      If you notice moisture or condensation on the windows when using your Procom Indoor Fireplace, refer to the air for combustion and ventilation requirements.
  • W
    wesley72Sep 2, 2025
    Why is my Procom FBD28T Indoor Fireplace making a whistling noise?
    • C
      Courtney WilkinsonSep 2, 2025
      If your Procom Indoor Fireplace produces a whistling noise when the burner is lit, turn the control knob to the low position and let it warm up for a minute. Operate the burner until air is removed from the line, and have the gas line checked by your local propane/LP gas company. Ensure you observe minimum installation clearances and clean the burner.

Summary

Safety Warnings

Gas Leak Detection and Response

Instructions on what to do if you smell gas, emphasizing immediate action and avoiding ignition sources.

General Safety and Operation Guidelines

Safety Precautions

General Safety Warnings

Crucial warnings about fire, explosion, carbon monoxide, and proper operation to prevent injury or death.

Carbon Monoxide Poisoning Dangers

Details the risks of carbon monoxide poisoning, its symptoms, and specific groups at higher risk.

Installation and Usage Restrictions

Product Features and Compliance

Air for Combustion and Ventilation

Importance of Ventilation

Highlights the necessity of adequate fresh air for proper combustion and ventilation in modern, energy-efficient homes.

Determining Ventilation Requirements

Ventilation Air Strategies

Installation Guidelines and Clearances

Clearance Requirements

Specifies minimum clearances to combustible materials for safe installation and operation.

Gas Selection

Built-in Fireplace Installation

Clearance to Combustibles

Visual diagrams and measurements for maintaining safe clearances from surrounding combustible materials.

Connecting to Gas Supply

Gas Supply Connection Warnings

Essential warnings and precautions for qualified technicians connecting the heater to gas lines.

Gas Connection Diagrams

Checking Gas Connections

Leak Detection Procedure

Instructions for safely checking all gas piping and connections for leaks using detection fluid.

Final Connections and Log Installation

Battery Installation and Pre-Lighting Safety

Pre-Lighting Safety Checks

Crucial safety steps and warnings to follow before attempting to light the pilot, including gas detection.

Lighting and Operation

Lighting Instructions

Step-by-step guide for safely lighting the pilot and main burner, including precautions and checks.

Burner Inspection and Operation

Pilot and Burner Flame Inspection

Guides on inspecting pilot and burner flame patterns for correct operation and potential issues like soot.

Care and Maintenance

Troubleshooting Ignition Issues

No Spark at Pilot

Identifies causes and solutions for when the ignitor button is pressed but no spark occurs at the ODS/pilot.

Pilot Flame Failure

Addresses issues where a spark is present but the pilot flame does not ignite or stay lit.

Troubleshooting Operational Problems

Pilot Flame Extinguishes

Solutions for when the pilot flame goes out after the control knob is released.

Burner Ignition and Combustion Issues

Troubleshooting steps for burners not lighting, delayed ignition, backfiring, and high yellow flames.

Troubleshooting Other Issues

Heater Shutoff and Gas Odor

Troubleshooting for the heater shutting off due to ODS operation or persistent gas odors.

Warranty Information

Procom FBD28T Specifications

General IconGeneral
BrandProcom
ModelFBD28T
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals