VENT-FREE GAS
FIREPLACE INSERT
OWNER’S OPERATION AND
INSTALLATION MANUAL
MODEL FBD32RT
PFS
®
US
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
WARNING: This appliance is equipped for Natural and
Propane gas. Field conversion is not permitted other than
between natural or propane gases.
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-866-573-0674, 8:00 am - 4:30 pm CST,
Monday through Friday or email customerservice@usaprocom.com

Questions and Answers

  • P
    Peter ThomasAug 19, 2025
    Why does my Procom FBD32RT produce unwanted odors?
    • G
      Greg EricksonAug 19, 2025
      If your Procom Indoor Fireplace produces unwanted odors, ventilate the room and stop using odor-causing products while the heater is running. If you have a gas leak, locate and correct all leaks. For propane/LP models, refill the supply tank.
  • K
    Kathleen LeeAug 21, 2025
    What to do if burner(s) does not light after ODS/pilot is lit on my Procom Indoor Fireplace?
    • K
      Katherine ScottAug 22, 2025
      If your Procom Indoor Fireplace burner(s) does not light after the ODS/pilot is lit, the burner orifice may be clogged. Clean the burner orifice or replace it. The burner orifice diameter might be too small, so replace the burner orifice. Also, the inlet gas pressure could be too low. In this case, contact your local gas supplier.
  • K
    Kevin LawrenceAug 23, 2025
    What to do if ODS/pilot lights but flame goes out when control knob is released on Procom FBD32RT?
    • R
      Roger DavisAug 25, 2025
      If the ODS/pilot lights but the flame goes out when the control knob is released on your Procom Indoor Fireplace, ensure the control knob is fully pressed in and hold it for 30 seconds after the pilot lights. Also, make sure the equipment shutoff valve is fully open. Check that the thermocouple connection is snug at the control valve, tightening it by hand until it's snug, then give it an additional 1/4 turn. Low gas pressure can cause this issue, so contact your local natural or propane/LP gas company. A dirty or partially clogged ODS/pilot can also be the cause, so clean or replace the ODS/pilot assembly. If the thermocouple is damaged, replace it. If the control valve is damaged, contact customer service.
  • A
    Amy MccallAug 26, 2025
    Why is there a gas odor even when control knob is in OFF position in Procom FBD32RT Indoor Fireplace?
    • R
      robin82Aug 26, 2025
      If you smell gas when the control knob is in the OFF position on your Procom Indoor Fireplace, there may be a gas leak. Locate and correct all leaks. If there is no leak, the control valve may be defective. In this case, contact customer service.
  • A
    Anthony GreenAug 28, 2025
    How to fix no spark at ODS/pilot when ignitor button is pressed in Procom FBD32RT Indoor Fireplace?
    • J
      Jennifer HuntAug 28, 2025
      If the ignitor button is pressed and there is no spark at the ODS/pilot of your Procom Indoor Fireplace, the ignitor electrode may be positioned wrong or broken, so replace the electrode. The ignitor electrode may not be connected to the ignitor cable, so replace the ignitor cable. The ignitor cable could be pinched or wet, so free the ignitor cable if pinched and keep it dry. A broken ignitor cable can cause this, so replace the ignitor cable. The piezo ignitor might be bad, so replace it. Also, check for a low battery and replace it if necessary.
  • M
    Michael RoseAug 30, 2025
    Why does my Procom FBD32RT shut off while in use?
    • T
      terri01Aug 30, 2025
      If your Procom Indoor Fireplace shuts off in use (ODS operates), there may not be enough fresh air available, so open a window or door for ventilation. Low line pressure can also cause this, so contact your local gas supplier. The ODS/pilot may be partially clogged, so clean the ODS/pilot.
  • I
    iwattsSep 3, 2025
    Why is there condensation on windows when using Procom FBD32RT?
    • C
      Charles JohnstonSep 3, 2025
      If you notice moisture or condensation on the windows when using your Procom Indoor Fireplace, it is likely due to not enough combustion/ventilation air.
  • K
    Kimberly HartSep 5, 2025
    Why is the flame high and yellow during burner combustion in my Procom FBD32RT Indoor Fireplace?
    • A
      Ashley BlankenshipSep 6, 2025
      If your Procom Indoor Fireplace has a high yellow flame during burner combustion, check the burner for dirt and debris and clean it if found. The gas regulator may be defective, so replace it. The inlet gas pressure may be too low, so contact your local gas supplier.
  • M
    Mr. Todd MooreSep 7, 2025
    What causes burner backfiring during combustion in Procom FBD32RT Indoor Fireplace?
    • K
      Kristina RodriguezSep 8, 2025
      If your Procom Indoor Fireplace burner backfires during combustion, the burner orifice may be clogged or damaged, so clean or replace the burner orifice. The burner may be damaged, so contact your dealer or customer service. The gas regulator may be damaged, so replace the gas regulator.
  • A
    Alejandra DuffySep 10, 2025
    What causes delayed ignition of burner(s) in Procom FBD32RT?
    • K
      Keith WatsonSep 10, 2025
      If your Procom Indoor Fireplace has delayed ignition of burner(s), the manifold pressure may be too low, so contact your local gas supplier. The burner orifice may be clogged, so clean the burner or replace the burner orifice.

Summary

Safety

Specifications

Qualified Installing Agency

Local Codes

Air for Combustion and Ventilation

Providing Adequate Ventilation

Discusses the need for adequate ventilation and defines classifications for air supply.

Determining Fresh-Air Flow for Heater Location

Provides a worksheet to calculate required fresh air based on space volume and appliance BTU input.

Installation

Minimum Wall and Ceiling Clearances

Specifies required clearances from combustible materials for safe installation.

Gas Selection

Details the process for changing the gas type from propane/LP to natural gas and vice versa.

Connecting to Gas Supply

Details safety precautions and requirements for connecting the heater to the gas supply.

Checking Gas Connections

Provides procedures for testing gas supply piping and heater connections for leaks.

Operation

Read Before Lighting

Crucial safety warnings and instructions to follow before attempting to light the appliance.

Lighting Instructions

Step-by-step guide on how to safely light the pilot and main burner.

Inspecting Burners

Care and Maintenance

Troubleshooting

Ignitor Problems

Lists common ignitor issues, possible causes, and corrective actions.

Pilot Flame Issues

Addresses problems with pilot flame not appearing or going out after release.

Burner Ignition and Flame Problems

Covers issues like burner not lighting, delayed ignition, backfiring, and high yellow flame.

Replacement Parts

Warranty

Procom FBD32RT Specifications

General IconGeneral
BrandProcom
ModelFBD32RT
CategoryIndoor Fireplace
LanguageEnglish