DESCRIPTION
Electric utility heaters are designed to meet a variety of heating requirements by switching
a few wires located in the base of the unit. Heat output is 25 589 BTU per hour. Features
horizontal and vertical flow horizontal air flow. Built-in thermostat with overheating safety
thermal cutout
SPECIFICATIONS
GENERAL SAFETY INFORMATION
:
: This heater requires hard wire installation (no plug). The
installation of this product must be carried out by a Certified Electrician
and in accordance with all local and national electrical codes.
NOTE: Compatible with a 240V Line Voltage Double Pole Wall
Thermostat. Must be installed by a Certified Electrician.
Read and understand all installation and operation
instructions and observe all safety instructions.
1. Use only copper wires rated for at least 60ºC.
2. Heater air flow must be directed parallel to or away from adjacent wall.
3. Observe wall, floor and ceiling clearance requirements
4. All wiring must be done according to national and local electrical codes in the united
states and the heater must be grounded as a precaution against possible electrical
shock. Heater circuit must be protected with proper fuses.
3
Rating AMPS BTU/hour
7500W 240V 31.3
25589
5000W 20.9
17065
Model
Voltage
HA24-50E
HA24-75E
240V