Between 1 and 4 sectors may be associated to
the four groups.
Next, the following screen is displayed, asking if
the clock should be interrupted in case of a failure in
the power supply.
Group 1 :
02 03 06 00
Clock stop on power
failure, Yes/No = No
In the program referring to the groups of sectors,
we will add 70 to the number of the group, group 1 =
71, group 2 = 72, etc. In the example on the previous
screen, a program will activate sectors 2, 3 and 6
when the value 71 is programmed in the risk sector
section.
If we choose the clock to be interrupted (answer-
ing “yes”), a cut in the supply will stop the clock, and
the programs in progress at the moment, and it will
not start again until the current returns.
In this case, all the programs will be completed,
although it will not be in real time. The user should
correct the clock, as soon as possible after the cut.
6.4. CLOCK PARAMETERS
The CLOCK option of the Parameters is used to
enter or modify the day of the week and the time.
If, on the other hand, the non interruption of the
clock is chosen, then if the cut in the supply is less
than 24 hours, when it returns, the unit will take up the
program at the corresponding chronological point. If
the shortcut is for more than 24 hours, when it returns,
all the outlets will be deactivated in wait for another
start.
To synchronize the seconds, do not press the
ENTER key at the minutes until the real seconds are
00.
Enter: Day, Hour, Min.
Mon.17:43
SUMMARY PARAMETERS SCREENS
FERTILIZATION FILTER CLEANING VARIOUS CLOCK
Number of
fertilizers, 0 to 4 = 3
Number of
filters = 3
By volume (Y/N) = Yes Enter: Day, Hour, Min.
Mon. 17:43
Minutes of
post-irrigation = 05
Working time
per filter = 067”
Irrigation pulse
value = 01000 L.
Clock stop on power
failure, Yes/No = No
Minutes of
separation = 02
Pause
between filters= 07”
Fertilizer pulse
value = 0100 cl.
Fert. Pump (Y/N) = Yes Irrigation minutes
bet. cleaning =0120
IC FC SC TM GM CS PS
1 2 0 5 0 3 4
Stop sectors = No TM Input detection
delay = 025”
Mixer 1 = Yes
Mixer 2 = Yes
Mixer 3 = Yes
Mixer 4 = No
GM Input detection
delay = 150”
Minutes of
pre-mixing = 02
CS Input detection
delay = 008”
Mixing minutes
on / off = 02 / 10
PS Input detection
delay = 300”
Advance/Delay
outlets = 005”
F1 F2 F3 F4 FP
12 11 10 -- --
M1 M2 M3 M4 C1- C3
--
09 -- -- 08 06
Enter groups
(Yes/No)= Yes
Group 1 :
02 03 06 00

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Progrés Agronic 2000 Series and is the answer not in the manual?

Progrés Agronic 2000 Series Specifications

General IconGeneral
BrandProgrés
ModelAgronic 2000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals