PROTEC AC-200-dual USER MANUAL
AC-200-dual
USER MANUAL

Questions and Answers

  • L
    Lori CoxAug 15, 2025
    What to do if there is no change in recovery volume in Protec Protection Device?
    • D
      Daniel RodriguezAug 15, 2025
      If the Protec Protection Device displays no change in recovery volume, first stop recovery. Then, check if the support screw of the gas cylinder load cell is loosened according to the 'Operation preparations' chapter. Finally, calibrate or change the gas cylinder load cell, or replace the PCA.
  • J
    John CruzAug 19, 2025
    Why does the recovery function not stop on my Protec AC-200-dual?
    • J
      James GriffithAug 19, 2025
      If the Protec Protection Device recovery function does not stop, it could be due to a leakage in the automotive A/C or equipment pipeline. Perform a leakage test, referring to the service manual for the machine leakage test. Alternatively, the compressor may not be working, in which case it should be replaced. A faulty pressure sensor can also cause this issue; try fastening the pressure sensor connection to the PCA or replacing the pressure sensor.
  • C
    Christine WilsonAug 21, 2025
    Why is my Protec AC-200-dual Protection Device charging slowly?
    • R
      Robert MasseyAug 22, 2025
      If the Protec Protection Device is not charging or is charging slowly, it could be due to insufficient refrigerant in the equipment. In this case, fill the equipment tank with more refrigerant. Another potential cause is a problem with the charge line. Inspect the charge line, including the tank red valve, tank red hose, solenoid #5, solenoid #9 (high side), solenoid #11 (long side), service hoses, and HP/LP quick couplers.
  • M
    Mark GarciaAug 25, 2025
    What to do if Protec AC-200-dual Protection Device displays high pressure alarm 004?
    • J
      James JohnsonAug 25, 2025
      If the Protec Protection Device shows 'High pressure alarm 004' but the gas cylinder gauge does not indicate excessive pressure, first check if the high pressure switch plug is disconnected from the PCA socket and fasten it. If the issue persists, inspect the hoses and connections between the compressor exit and the tank blue hand valve for any blockages.
  • J
    joshuazunigaAug 27, 2025
    How to fix no display on Protec Protection Device?
    • C
      christina78Aug 27, 2025
      If your Protec Protection Device has no display, the fuse may be fused in the power cable connection box or PCA; try changing the fuses. The PCA might be burnt, requiring a PCA replacement. A loosened power cable could also be the cause, so ensure it's reliably connected. Lastly, the LCD may not be working, in which case, replace the LCD.
  • W
    werneramberAug 30, 2025
    Why is the vacuum pump injecting oil in my Protec AC-200-dual Protection Device?
    • S
      Sean CalderonAug 30, 2025
      If the vacuum pump of the Protec Protection Device is injecting oil, it may be due to an excessive oil volume. Discharge some oil to the proper level. Alternatively, the entrance pressure could be too high; try running the Recovery function first.
  • G
    Gloria JacksonSep 3, 2025
    How to fix low vacuum degree in Protec AC-200-dual?
    • M
      maria54Sep 3, 2025
      To address a low vacuum degree in the Protec Protection Device, start by adding oil to the central line if the vacuum pump oil is insufficient. If the pump oil is emulsified or dirty, replace it with new oil. Also, check for a plugged pump oil inlet and clean it if necessary. Examine the pump connection for any leakage and ensure the connection is secure. Lastly, maintain the machine, paying special attention to o-rings, washers, and other sealing parts that may be worn out.
  • M
    Mary MillsSep 5, 2025
    What does alarm 005 mean on Protec AC-200-dual Protection Device?
    • H
      hschaeferSep 5, 2025
      If the Protec Protection Device displays alarm 005 while the auto A/C has refrigerant, it indicates that the low pressure switch plug is disconnected from the PCA socket. Fasten the low pressure switch plug to resolve this issue.
  • S
    Susan JimenezSep 9, 2025
    What to do if vacuum pump is pressurized during recovery of Protec Protection Device?
    • P
      pgarnerSep 9, 2025
      If, during recovery, the vacuum pump in your Protec Protection Device is pressurized and there's too much oil in it after a period, it suggests that the contact between solenoid valve #8 and the valve base is not well sealed. To resolve this, remove solenoid #8 from the valve base and clean both the solenoid valve and the valve base.
  • A
    Adam BrownSep 12, 2025
    Why is there suction in the old oil bottle during vacuum in Protec AC-200-dual?
    • K
      Kevin RodriguezSep 12, 2025
      If there is suction in the old oil bottle during vacuum in your Protec Protection Device, the contact between solenoid valve #2 and the valve base is likely not well sealed. Remove solenoid #2 from the valve base and clean both the solenoid valve and the valve base.

Summary

General Safety

Safety Precautions

Summarizes key safety rules for operation and handling to prevent accidents and equipment damage.

Specifications

Technical Specifications

Lists key performance and dimension details including power, capacity, and pressure ranges.

Equipment Description

Component Locations

Identifies major parts and their positions on the machine through visual diagrams.

Operation Preparations

Unlock Load Cells

Procedure for preparing the refrigerant tanks by removing lock bolts before use.

Fill Equipment with Refrigerant

Steps for initial charging of refrigerant and refrigeration oil into the equipment.

Equipment Connection

System Connections Diagram

Visual guide illustrating how to connect hoses for recovery, vacuum, oil injection, and charge.

Main Functions

Recovery Process

Details on recovering and purifying refrigerant from an A/C system to the equipment tank.

Vacuum Process

Procedure for evacuating air and moisture from the A/C system.

Oil Injection

Steps for injecting refrigeration oil into the automotive A/C system.

Charge Process

Instructions for charging refrigerant into the automotive A/C system.

Tank Fill Operation

Procedure for filling or adding refrigerant into the machine's storage cylinders.

Automatic Mode

Description of performing a full cycle of operations automatically.

System Setting

Setting Options

Covers language, calibration, database, unit set, container weight, and component tests.

Update Procedure

Software Update

Step-by-step guide for updating the machine's software via USB.

Service Reminding

Maintenance Alerts

Information on the machine's operation count for service reminders and maintenance.

Main Troubleshooting

Troubleshooting Guide

Lists common malfunctions with their reasons and suggested solutions.