TEKTINO AC-200-dual USER MANUAL V2.30
2
/14
Specifications:
DimensionPackage 710*660*1190mm; Unpacked machine 610*595*1075mm
3
Input powerAC220V±10~50/60Hzor AC110V±10~60Hz
Pre-ventilation: the machine makes 30 seconds ventilation, before it is powered on.
Compressor power3/8HP
Average gas state refrigerant recovery speed (through charge/suction port)0.25Kg/min.
Hand valves free.
Recovery rate: 96%.
Vacuum pump capacity120L/min, non-sparkle.
Accuracy of gas cylinder load cell±10g
Capacity of dual gas cylinders (one for R-134a, one for HFO-1234yf) 10KG
New oil bottle capacity250ml
Used oil bottle capacity: 400ml
Dual condensers and cooling fans, one for R-134a, one for HFO-1234yf
Max. Pressure20bar
Charge speed2Kg/Min(max.)
LCD display4.3-inch,TFT full color
High pressure gauge range-1bar~40bar
Low pressure gauge range-1bar~22bar
A/C database included, update through USB port.
Automatic service reminding. The equipment provides 600 operations totally (each recovery or vacuum
counts for one operation, and automatic mode counts for 2 operations) between regular maintenance, When
600 operations have been made the machine automatically reminds to call distributor for service.