1
MODEL OF PTronik
CONTROLLER
Indicates the model of the PTronik controller. Visually the E10, Eco and ECo
look very similar.
2
COUNT DOWN TIME Indicates the time in seconds until the next valve pulses.
3
NEXT VALVE Indicates the next valve that will pulse. This will be a number between 1 and
240 depending on setup and how many extension cards are connected.
4
PERCENTAGE
SAVINGS
Indicates the number of pulses saved operating in differential pressure
mode when compared to a sequential timer with identical on and offtime
settings. The higher to valve the greater the savings achieved.
5
DIFFERENTIAL
PRESSURE SENSOR
Indicates what the ECo is using to control the dust collector
DP = The ECo is using the internal differential pressure sensor
XDP = The ECo is using an external differential pressure sensor
6
DIFFERENTIAL
PRESSURE VALUE
Indicates the current differential pressure over the filter bags. The units of
measurement can be
mmH20 = mm of water column
inH20 = inches of water column
kPa = kilopascals
7
DIFFERENTIAL
PRESSURE ALARM
Indicates what alarm level the current differential pressure reading is at, this
is a user defined setting
U Low = Ultra Low Differential Pressure
Low = Low Differential Pressure
High = High Differential Pressure, timer OFF time 1 active
Fast = Higher Differential Pressure, timer OFF Time 2 active
Alarm = Differential Pressure above selected alarm level
8
ALARM STATE Indicates the alarm status for alarms 1 to 8 (the screen will toggle between
A1IA2IA3-A4+ and A5IA6-A7-A8-).
I = Interrupt
- = alarm disabled
+ = alarm enabled
* = alarm enabled and ON (activated)
9
SOLENOID STATE Indicates the last solenoid valve that fired and what the result of the valve as
(whether the coil of the last valve is faulty or not).
OK = NO Fault
OC = Open Circuit
SC = Short Circuit
10
TUBE CLEANER Indicates the number of times the tube cleaning valves have fired
11
MANUALLY
STOPPING THE DUST
COLLECTOR
Indicates the current state of the controller. The dust collector can be
manually halted if required.
Halt = The dust collector has been halted either manually or by the
differential pressure cleaning mode
Pulse = The dust collector is pulsing
12
MODE OF
OPERATION
Changes the operation of the dust collector from between manual
(sequential) or auto (on demand) modes
Auto= The dust collector is running in on demand mode, it is using
the differential pressure sensor to control the pulsing
Man = The dust collector is running in manual mode and is
operating as a basic sequential timer