UZK24.262/-E1, UZO24.262/-E1
BATTERY MODULE 24V, 26AH, 40A
Apr. 2022 / Rev. 0.3 DS-UZK/UZO24.262-xx-EN
All parameters are typical values specified at 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
Operational temperature
*)
-10°C to +50°C (14°F to 122°F)
For charging
Frequently charging below +5°C (41°F) reduced the
lifetime of the battery
-15°C to +50°C (5°F to 122°F)
-15°C to +50°C (5°F to 122°F)
For discharging @50A
For discharging @40A
-20°C to +50°C (-4°F to 122°F)
For storage and transportation
Recommendation:
For best performance and lifetime do not store at
temperatures higher than 25°C.
IEC 60068-2-30
Do not energize while condensation is present
±4mm at 16.7Hz
fixed frequency for 1hour
Vibration in vertical mounting orientation
according to IEC/EN 61056-1
free fall from 20cm
onto a wooden floor
Shock with bottom down orientation according to
IEC/EN 61056-1
0 to 6000m (0 to 20 000ft)
According to IEC 62477-1, not conductive
*) Operational temperature is the same as the ambient temperature and is defined as the air temperature 2cm below the unit.
Fig. 8-1 Temperature Effects in Relation to Battery Capacity
0
20
100
120%
80
60
40
Percentage of capacity available
50° C
122° F
-20°
-4°
-10°
14°
0°
32°
10°
50°
20°
68°
30°
86°
40°
104°
Temperature