EasyManua.ls Logo

Puls U Series - Environment

Default Icon
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UZK24.262/-E1, UZO24.262/-E1
U-Series
BATTERY MODULE 24V, 26AH, 40A
Apr. 2022 / Rev. 0.3 DS-UZK/UZO24.262-xx-EN
All parameters are typical values specified at 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
6/11
8. ENVIRONMENT
Operational temperature
*)
-10°C to +50°C (14°F to 122°F)
For charging
Frequently charging below +5°C (41°F) reduced the
lifetime of the battery
-15°C to +50°C (5°F to 122°F)
-15°C to +50°C (5°F to 122°F)
For discharging @50A
For discharging @40A
Storage temperature
-20°C to +50°C (-4°F to 122°F)
For storage and transportation
Recommendation:
For best performance and lifetime do not store at
temperatures higher than 25°C.
Humidity
5 to 95% r.h.
IEC 60068-2-30
Do not energize while condensation is present
Vibration sinusoidal
±4mm at 16.7Hz
fixed frequency for 1hour
Vibration in vertical mounting orientation
according to IEC/EN 61056-1
Shock
free fall from 20cm
onto a wooden floor
Shock with bottom down orientation according to
IEC/EN 61056-1
Altitude
0 to 6000m (0 to 20 000ft)
Degree of pollution
2
According to IEC 62477-1, not conductive
*) Operational temperature is the same as the ambient temperature and is defined as the air temperature 2cm below the unit.
Fig. 8-1 Temperature Effects in Relation to Battery Capacity
0
20
100
120%
80
60
40
Percentage of capacity available
50° C
122° F
-20°
-
-10°
14°
32°
10°
50°
20°
68°
30°
86°
40°
104°
Temperature