6
133
134
7
The device can be powered with an external power supply such as 
Power Bank (5V).
Connect the external power supply to the USB port (15) of the device 
(Pic. 1 on the flyleaf). 
The device switches to operation from external power supply, and the 
IPS5 Battery Pack will begin slowly charging. 
The display will  show the battery  icon           with charge level as a 
percentage. 
If the device operates on external power supply but the IPS5 battery is 
not connected, the icon        is shown. 
When the external power supply is disconnected, the device switches 
to the internal battery pack without powering off. 
WARNING! Do not point the objective lens of the device at intensive 
sources of light such device emitting laser radiation or the sun. This 
may render the electronic components inoperative. The warranty 
does not cover damage caused by improper operation.
WARNING! The radiator cooling system (12) becomes warm during 
operation: this is normal and allows an increase in the sensitivity of 
the device. 
8
Powering on and image setup  
Open the lens cover  .(13)
T device ON/OFF (1) urn the   on with a short press of the  button.
Adjust  the  interpupillary  distance  with  the  rings  (6)  by  moving  the 
eyepieces farther or closer to each other. 
To obtain a crisp image of the icons on the display, rotate the dioptre 
adjustment ring   .  there is no need to rotate the s (7)  Once adjusted,
dioptre adjustment ring for distance or any other conditions. 
To focus on the object being observed rotate the lens focusing 
ring  .(8)
To  set  up  display  brightness  and  contrast  and  continuous  zoom, 
please refer to the   MENU FUNCTIONS section. QUICK
A press and   ON/OFF  devicefter use,  hold down the button to turn the   
off.
Never use a modified or damaged charger. 
Do not leave the Battery Pack with a charger connected to the 
mains longer than 24 hours after full charge. 
Do not expose the battery pack to high temperature or to a naked 
flame. 
Do not submerge the battery in water. 
Do not connect external device with a current consumption that 
exceeds permitted levels. 
The Battery Pack is short circuit protected. However, any situation 
that may cause short-circuiting should be avoided. 
Do not dismantle or deform the Battery Pack. 
Do not drop or hit the battery.
When using the battery at negative temperatures, battery's capacity 
decreases, this is normal and is not a defect.  
Do not use the battery at the temperatures above those shown in 
the table – this may decrease battery's life. 
Keep the battery out of the reach of children.  
9
Calibration  allows  levelling  of  the  background  temperature  of  the 
microbolometer  and  eliminates  image  flaws  (such  as  frozen  image, 
vertical stripes etc.). 
There are three calibration modes: 
manual (M), semi-automatic (SA) and automatic (А). 
EXTERNAL POWER SUPPLY
OPERATION