Press
the
MENU
3
button
briefly
to
enter
the
submenu
.
Use
the
UP
4/
DOWN
2
buttons
to
select
one
of
the
calibration
modes
described
below
.
Press
the
MENU
3
button
briefly
to
confirm
the
selection
.
M
mode
Manual
Close
the
lens
cover
7
.
Press
the
ON
/
OFF
5
button
briefly
.
Open
the
lens
cover
7
after
the
calibration
is
completed
.
SA
mode
Semi
-
Automatic
)
The
user
independently
determines
the
need
for
calibration
(
according
to
the
image
being
observed
).
Press
the
ON
/
OFF
5
button
briefly
to
activate
calibration
.
There
is
no
need
to
close
the
lens
cover
because
an
internal
shutter
covers
the
microbolometer
automatically
.
A
mode
Automatic
)
The
device
is
calibrated
autonomously
according
to
firmware
algorithms
.
There
is
no
need
to
close
the
lens
cover
because
an
internal
shutter
covers
the
microbolometer
automatically
.
In
this
mode
,
the
user
can
still
choose
to
calibrate
the
device
using
the
ON
/
OFF
5
button
if
required
(
as
in
the
SA
mode
).
In
Automatic
calibration
mode
a
countdown
timer
will
appear
instead
of
the
calibration
mode
icon
3
seconds
before
automatic
calibration
begins
.
Notes
:
During
calibration
,
the
image
on
the
display
briefly
freezes
for
up
to
1
second
.
The
selected
calibration
mode
is
saved
after
restarting
the
device
.