EasyManua.ls Logo

Pure Enrichment MistAire Studio - User Manual

Pure Enrichment MistAire Studio
7 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
55
YEARYEAR
WARRANTYWARRANTY
ULTRASONIC COOL MIST HUMIDIFIERULTRASONIC COOL MIST HUMIDIFIER
MISTAIRE STUDIOSTUDIO
USER MANUALUSER MANUAL
MODEL: PEHUMSMLMODEL: PEHUMSML

Questions and Answers

Summary

Warnings and Precautions

FCC Notice

Introduction

Using the Humidifier

Setup

Instructions for placing the humidifier in a suitable location for optimal airflow and safety.

Filling

Step-by-step guide on how to safely and correctly fill the humidifier's water tank.

Functions & Features

Power Button

Details on how the power button controls mist settings and the night light, plus indicator lights.

Cleaning Brush

Information about the included cleaning brush for maintaining the ultrasonic disk.

Cleaning

General Cleaning

Instructions for cleaning the interior base, water tank, and exterior surfaces of the humidifier.

Descaling

Guidance on removing mineral scale build-up, recommending distilled water and specific cleaners.

Ultrasonic Disk

Steps to clean the ultrasonic disk using the provided brush to remove deposits.

End of Season Storage

Troubleshooting

Warranty

Product Registration

Overview

The MistAire Studio (Model: PEHUMSML) is an ultrasonic cool mist humidifier designed to moisturize dry air in personal spaces or small rooms up to 175 sq ft. It comes with a 5-year warranty from Pure Enrichment.

Function Description:

The humidifier operates by releasing a cool mist into the air, increasing humidity levels. It features a power button that controls both the mist settings (low and high) and an optional night light. The power button's blue light indicates correct operation and turns off automatically after about 10 seconds at the desired setting. If the unit runs out of water, the light turns red, and the unit automatically shuts off. To continue use, simply refill the water tank. The device is designed for ease of use with a simple filling process and includes a cleaning brush for maintenance.

Important Technical Specifications:

  • Size: 9" x 5" x 5"
  • Power: AC 100-240V, 60Hz
  • Room Coverage: Up to 175 sq ft
  • Max Run Time: 10 hours (low setting); 7 hours (high setting)
  • Tank Capacity: 0.7 liters (34 fl oz)
  • Moisture Output: ≤60ml/hr (low setting); ≥80ml/hr (high setting)
  • Noise Level: <32dB

Usage Features:

  • Setup: Place the humidifier on a firm, flat, and level water-resistant surface, at least six inches from any walls or objects, to ensure proper airflow and prevent water damage to furniture or flooring. Do not place it directly on carpet, towels, blankets, or other absorbent surfaces.
  • Filling:
    1. Ensure the unit is unplugged.
    2. Separate the water tank from the base.
    3. Flip the water tank over and open the tank lid by turning it to the left.
    4. Pour cool, clean water directly into the tank. Do not add anything other than water.
    5. Close the tank lid by turning it to the right, ensuring it is firmly secured.
    6. Attach the filled tank to the base of the unit. Note: Always ensure there is water in the unit before turning it on.
  • Power Button Operation:
    • 1st press: Low mist setting, night light off.
    • 2nd press: Low mist setting, night light on.
    • 3rd press: High mist setting, night light on.
    • 4th press: High mist setting, night light off.
  • Safety Precautions:
    • Keep out of reach of children and pets.
    • Do not disassemble, repair, or remodel the unit.
    • Do not tilt or move the unit when it is plugged in.
    • Do not remove the water tank while the unit is on.
    • Do not handle the plug with wet hands.
    • Avoid bending, twisting, pulling, or damaging the power cord.
    • Do not point the humidity spout directly at objects or people.
    • Do not inhale the mist or drink water from the tank.
    • Do not fill the tank with hot or boiling water.
    • Avoid direct sunlight or proximity to heat sources.
    • Do not use if the water tank is cracked or damaged.
    • Do not leave running unattended for extended periods or around children.
    • Unplug when not in use or when no one is home.
    • Do not keep water in the tank when not in use.
    • Do not use water additives like essential oils, fragrances, or eucalyptus, as they can damage the appliance.
    • Do not cover the mist nozzle.
    • Do not put objects in the tank.
    • Hold the humidifier securely when unplugging.
    • Do not place the power cord over objects or get water on it.
    • Do not use near a sink.
    • Do not touch the water tank during operation.
    • Do not submerge the unit in water or pour water on the unit or in the humidity spout.
    • Use clean or distilled water; hard water areas will require more frequent cleaning.

Maintenance Features:

  • General Cleaning (Always unplug before servicing):
    • Inside the base: Pour out excess water. Wash with fresh water using the included cleaning brush and a soft cloth. Do not submerge the base or allow water to enter the dry air exhaust port.
    • Water tank: Empty the tank. Remove the mist nozzle and clean the mist tube with fresh water and a bottle cleaning brush (not included).
    • Outer surface: Wipe with a soft, damp cloth. If water accumulates, reduce humidity and dry the surface.
  • Descaling:
    • Depending on usage and water type, cleaning to remove scale may be needed weekly or every other week.
    • Distilled water is recommended in hard water areas to reduce mineral precipitation ("white dust").
    • Do not use harsh detergents or cleaning chemicals. Decalcification cartridges or humidifier cleaner capsules can be used to prevent hard mineral deposits.
  • Ultrasonic Disk Cleaning:
    1. Unplug the humidifier.
    2. Remove the tank and empty all water from the base and tank.
    3. Locate the ultrasonic disk (refer to diagram on page 6).
    4. Use the enclosed cleaning brush to gently clean and remove buildup. Note: Do not scrub or scrape the ultrasonic disk.
  • Removing Stubborn Scale:
    1. Fill the base with a mixture of 1 tsp white vinegar and 1 tsp water.
    2. Let the solution stand for 5 minutes.
    3. While the vinegar is in the base, clean interior surfaces with a soft cloth or brush.
    4. Check and clean any buildup in the mist nozzle and mist tube.
    5. Rinse the base thoroughly to remove scale and vinegar solution.
    6. If white dust persists due to minerals, consider using a decalcification or humidifier cleaner cartridge.
  • End of Season Storage:
    • Follow general cleaning and descaling instructions.
    • Completely dry the humidifier before storing. Do not store with water inside.
    • Pack the unit in its original box and store in a cool, dry location.
  • Troubleshooting: The manual provides solutions for common issues such as no vapor, low humidity, bad smell, white dust, unit stopping, water accumulation, dripping during refilling, increased noise, and red light on the power dial. It emphasizes not to open the motor housing, as this will void the warranty and could cause damage or injury.

Pure Enrichment MistAire Studio Specifications

General IconGeneral
BrandPure Enrichment
ModelMistAire Studio
CategoryHumidifier
LanguageEnglish

Related product manuals