EasyManua.ls Logo

Pure Humidifier ES Series - User Manual

Default Icon
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
Standard Water
“ES” Series
Electric Humidifier
Installation Instructions
Operation and Maintenance Manual
Our results are comforting
Form No: ESOM-3-16
Read and Save These Instructions
ETL LISTED HUMIDIFIER
PURE HUMIDIFIER
®
and INTAC
®
are registered trademarks of PURE Humidifier Co.

Other manuals for Pure Humidifier ES Series

Questions and Answers

  • J
    Joseph GibsonAug 9, 2025
    What to do if Pure Humidifier ES Humidifier will not fill?
    • J
      Jeremy WilsonAug 9, 2025
      If your Pure Humidifier won't fill, first, check the water supply to ensure there is water pressure. Next, make sure the drain ball valve is closed. If you have an auto drain system, check that the drain valve is closed by removing the actuator and looking at the valve stem position. Finally, check the fill relay to see if it is energized.
  • J
    Justin OconnellAug 19, 2025
    Why does Pure Humidifier Humidifier not stop filling or is short cycling?
    • R
      Richard RoblesAug 19, 2025
      If your Pure Humidifier Humidifier does not stop filling or is short cycling, several issues could be the cause. Start by checking the fill relay to see if it is energized; if there's no voltage, check for dirt under the valve seat. Also, ensure the drain ball valve is closed. If you have an auto drain system, verify the drain valve is closed by removing the actuator and checking the valve stem position. Clean the probe ends of the Tri-Probe sensor, and ensure the Tri-Probe wiring matches the wiring diagram on the PLC.
  • A
    Amy WatkinsAug 28, 2025
    How to fix Pure Humidifier ES that will not heat?
    • J
      jermaine02Aug 28, 2025
      If your Pure Humidifier Humidifier will not heat, check and replace any blown main heater fuses. Verify the control transformer is producing 24VAC control voltage by checking the transformer output and verifying voltage across 24VAC Fused & 24VAC Com. Ensure all safety controls are completing the safety circuit. Verify the voltage to and from the humidity sensor, and check/verify the heater voltage and amperage, comparing it to the diagram or nameplate ratings.

Summary

Electrical Specifications

Location and Mounting Guidance

Mounting Options Overview

Hose Kit Installation Procedure

Steam Supply Piping Examples

Water and Drain Piping Requirements

Pre-Startup Installation Checklist

Humidifier Start-Up Procedure

Installation Verification for Start-Up

Confirms all installation procedures are completed correctly before powering on the unit.

Initial Operation and Safety Checks

Details turning on the unit, setting parameters, and verifying operational safety circuits.

Periodic Maintenance Instructions

ES Series Maintenance Schedule

Lists items to inspect semi-annually, including fill valve, interlocks, heaters, and probes.

Troubleshooting Common Issues

Pure Humidifier ES Series Specifications

General IconGeneral
TypeEvaporative
Coverage Area500 sq ft
Water Tank Capacity1.5 gallons
Run TimeUp to 24 hours
Speeds3
HumidistatYes
Auto Shut-offYes

Related product manuals