EasyManua.ls Logo

Purkeys 1200+ - Inverter Troubleshooting; DC Input Power Issues; AC Output Power Issues

Purkeys 1200+
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net
1200+ WITH TIMER V1.00
OWNERS MANUAL
9
INVERTER TROUBLESHOOTING
DC Input Power Issues
TROUBLE/INDICATION
POSSIBIBLE CAUSE
No AC output: yellow LED lit;
green LED not lit
DC input below 10.5 volts
No AC output; Red and Green LED
not lit.
Inverter fuse cube open
Low battery alarm sounds
abnormal
Bad connection or wiring issues
Low battery alarm sound
Low battery voltage
Yellow LED lit when power is on
weak batteries or cables issues
AC Output power issues
No AC output; Yellow LED lit;
Green LED not lit
Inverter overheat
No AC output; Red and Green LE
not lit
Inverter output power limited
by overload/short circuit
protection circuit
TV/Radio interference; snow in
picture, buzz in speakers
Appliance too close to inverter
Motorized power tool won't start
Excessive start up load
Motorized power tool does not
operate at correct speed
Purely inductive load