EasyManua.ls Logo

Pyle PDMT25 - DC Current Measurement Specifications; AC Current Measurement Specifications

Pyle PDMT25
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Range Resolution Accuracy
400.0uA 0.1uA
4000uA 1uA
40.00mA 10uA
400.0mA 100uA
+
1.2% of rdg + 3 digits
10A 10mA +2.5% of rdg + 3 digits
Overload Protection: 0.5A / 1000V and 10A / 1000V Fuse.
Maximum Input: 400uA dc on uA range
400mA dc on mA range
10A dc on 10A range.
AC Current (Auto-ranging)
Range Resolution Accuracy
400.0uA 0.1uA
4000uA 1uA
40.00mA 10uA
400.0mA 100uA
+
1.5% of rdg + 5 digits
10A 10mA +3.0% of rdg + 5 digits
Overload Protection: 0.5A / 1000V and 10A / 1000V Fuse.
AC Response: 50 Hz to 60 Hz
Maximum Input: 400uA ac rms on uA
400mA ac rms on mA
10A ac rms on 10A range.