Explains the caution symbol indicating a need to refer to instructions for personal safety or damage prevention.
Explains the warning symbol for hazardous situations that could result in death or serious injury.
Explains a caution symbol indicating a hazardous situation that may result in product damage.
Advises that marked terminals must not exceed 1000 VAC or VDC with respect to earth ground.
Indicates equipment is protected by double insulation, signifying safety compliance.
Indicates that the equipment complies with current European Union directives.
Explains the symbol indicating continuity testing functionality.
Indicates when the battery voltage drops below the operating level.
Explains the symbol related to diode testing functionality.
Allows the meter to "freeze" a measurement for later reference.
Automatically selects the best range for measurements.
Represents alternating current or voltage measurements.
Represents direct current or voltage measurements.
Stores the highest or lowest measurement for later reference.
Finds glitches and transients without a scope.
Controls the display illumination.
Indicates measurement in Volts.
Indicates measurement in Amperes, milliAmperes, or microAmperes.
Selects AC/DC measurement modes for various functions like Voltage, Amps, etc.
Allows the meter to "freeze" a measurement for later reference.
Switches the display light on or off.
Captures highest/lowest measurements and allows mode selection.
Specifies insulation class as Class 2, Double insulation.
Details overvoltage categories CAT IV 600V and CAT III 1000V.
States the maximum voltage between terminals and earth ground is 1000V RMS.
Specifies surge protection as 8kV peak per IEC 61010.
Describes the display as a 4000-count LCD, 21mm high.
Indicates automatic polarity detection and negative polarity indication.
Specifies the "OL" mark for over-range conditions.
Describes the battery symbol indicating low battery voltage.
Specifies the measurement rate as 2 times per second nominal.
Meter automatically shuts down after approximately 30 minutes of inactivity.
Specifies operating temperature and humidity ranges.
Specifies storage temperature and humidity ranges.
Details acceptable relative humidity levels at different temperatures.
Specifies maximum operating and storage altitudes.
Indicates the pollution degree rating for safety standards.
States compliance with relevant IEC/EN safety standards.
Specifies the power source as a 9V battery (NEDA 1604, IEC 6F22).
Provides the physical dimensions of the multimeter.
States the approximate weight of the multimeter.
Specifies the conditions under which accuracy is guaranteed.
| Category | Multimeter |
|---|---|
| Model | PDMT25 |
| Display | LCD |
| DC Voltage Range | 200mV/2V/20V/200V/600V |
| AC Voltage Range | 200V/600V |
| Diode Test | Yes |
| Continuity Buzzer | Yes |
| Transistor Test | Yes |
| Data Hold | Yes |
| Auto Power Off | Yes |
| Power Source | 9V Battery |
| Safety Rating | CAT II 600V |
| DC Current Range | 200μA/2mA/20mA/200mA/10A |
| Resistance Range | 200Ω/2kΩ/20kΩ/200kΩ/2MΩ |
| Capacitance Range | 20nF/200nF/2μF/20μF/200μF |
| Frequency Range | 2MHz/10MHz |