15
2) For External cable kits:
NOTE
Power and communication cables to connect to inverter belongs to an External
Cable Kit, NOT include in battery carton box. They are in another extra
small cable box. If there is anything missed please contact dealer.
Two 4AWG power cables (peak current capacity 120A, constant 100A) and
RJ45 communication cable for each energy storage system:
For the external cables, the length shall less than 3 meters.
SN of RJ45cable
Mark
Pin
WI0SCAN30RJ1
With blue mark:
Battery-Inverter
Pin1~3: NULL
Pin4~8: pin to pin
For connection
to inverter
WI0SCAN35RJ3
With silver mark:
Battery-Battery
Pin1~8: pin to pin
For parallel
connection
between master
batteries