EasyManua.ls Logo

Python 750 - Table of Zones

Python 750
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 1995,1997 Directed Electronics, Inc. Vista, CA 11 97N437.597
H1/11 RED
(+)12V constant power input: Before connecting this wire, remove the supplied fuse. Connect to the battery
positive terminal or the constant 12V supply to the ignition switch as described on Page 5.
NOTE: Always use a fuse within 12 inches of the point you obtain (+)12V. Do not use the 10A fuse in the
harness for this purpose. This fuse protects the module itself.
H1/12 RED/WHITE
channel 2, 200mA (-) output: When the system receives the code controlling channel, for longer
than 1.5 seconds, the red/white will supply an output as long as the transmission continues. This is often used to
operate a trunk/hatch release or other relay-driven function.
IMPORTANT! Never use this wire to drive anything but a relay or a low-current input! The transistorized output
can only supply 200 mA of current, connecting directly to a solenoid, motor, or other high-current device will
cause it to fail.
(+) 12V CONSTANT FUSED
RED/WHITE H1/1
FUNCTION 2 OUTPUT
(+)12V IF (+) SWITCHED
(-) GROUND IF (-) SWITCHED
SWITCHED TRUNK RELEASE WIRE
87
87A
85
86
30
RED/WHITE H1/12
CHANNEL 2 OUTPUT
PLUG-IN LED AND VALET
®
/ PROGRAM SWITCH
These plug into the module. The Status LED plugs into the small two-pin socket, while the Valet
®
/Program Switch
should be plugged into the larger blue two-pin connector. The Status LED fits in a 9/32" hole.
Status LED Valet
®
/Program Switch
GREEN
(-) Multiplex input: Inputs shorter than .8 seconds will trigger the Warn Away
®
response, while inputs longer
than .8 seconds will trigger full alarm sequence and report zone four. If installing an optional DEI
®
dual stage sensor,
connect to the GREEN wire as shown below. The diagram below eliminates the need for diodes to isolate the sensors,
as well as providing a seperate zone for each sensor.
Diagram for adding optional DEI
®
dual stage sensor to GREEN wire (zone 4)
BLUE
(-) Multiplex input: Inputs shorter than .8 seconds will trigger the Warn Away
®
response, while inputs longer than
.8 seconds will trigger full alarm sequence and report zone two.
RED, BLACK
: RED is (+)12V constant, BLACK is (-) ground. Do not use these for anything besides the plug in
shock sensor.
FOUR-PIN SHOCK SENSOR HARNESS
xx
CUT
BLUE WIRE OF PRE-
WIRED PLUG
GREEN WIRE OF PRE-
WIRED PLUG
BLUE WIRE FROM PLUG-
IN SHOCK SENSOR
GREEN WIRE FROM
PLUG-IN SHOCK SENSOR
BLUE AND GREEN WIRES
FROM DEI
®
DUAL STAGE
SENSOR

Other manuals for Python 750

Related product manuals