EasyManua.ls Logo

Qlima P522 - User Manual

Qlima P522
120 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
P522 - P528 - P534 - PH534
6
4
u
:
=
BRUGSANVISNING
KÄYTTÖOHJE
OPERATING MANUAL
BRUKSANVISNING
INSTRUKCJA OBSŁUGI
BRUKSANVISNING
10
28
46
64
82
102

Other manuals for Qlima P522

Questions and Answers

  • A
    abigailowensJul 25, 2025
    Why is my Qlima P522 Air Conditioner not cooling the room?
    • M
      Mary PittsJul 26, 2025
      If your Qlima Air Conditioner isn't cooling the room, ensure that all doors, windows, and curtains are closed, keeping in mind the 'tips for correct use'. Also, try to eliminate any heat sources in the room, such as ovens or hair dryers. Check that the air exhaust hose is correctly fitted to the housing at the back of the unit. Finally, consider whether the unit's technical specifications are adequate for the room size.
  • L
    lhallAug 1, 2025
    What to do if Qlima P522 works for a short time only?
    • R
      ryanmorenoAug 1, 2025
      If your Qlima Air Conditioner works for only a short time, it might be due to bends in the air exhaust hose. Ensure the air exhaust hose is correctly positioned, keeping it as short and free of curves as possible to avoid bottlenecks. Also, check for and remove any obstacles obstructing air discharge.
  • J
    Jessica FoxAug 8, 2025
    Why Qlima P522 does not operate for about three minutes after restarting it?
    • L
      Lori HartAug 9, 2025
      If your Qlima Air Conditioner doesn't operate for about three minutes after restarting, this is likely because the internal compressor safety device prevents restarting until three minutes have passed. This delay is part of normal operation, so please wait.
  • W
    Wanda HendricksAug 17, 2025
    Why is there an unpleasant smell in the room when operating Qlima P522 Air Conditioner?
    • X
      xpowellAug 17, 2025
      If there is an unpleasant smell in the room during operation of your Qlima Air Conditioner, the air filter may be clogged. Clean the filter as described there is an above.

Summary

General Safety

Safety Instructions

Installation Instructions

Exhausting Hot Air

Instructions for exhausting hot air from the unit into the window.

Window Slider Kit Installation

Details on how to install the window slider kit for the exhaust hose.

Control Panel Operation

Cool Mode Operation

Heat Mode Operation

Self-Diagnosis and Error Messages

Remote Control Operation

Cleaning Air Filters

Water Drainage Method

Troubleshooting

Guarantee Conditions

Qlima P522 Specifications

General IconGeneral
TypeMonobloc mobile air conditioner
TimerYes
Noise level65 dB
Number of speeds3
Airflow (high speed)330 m³/h
Refrigerating mediumR410A
Cooling capacity (max)- BTU/h
Dehumidifying capacity0.7 l/h
Air conditioner functionsCooling, Dehumidifying
Cooling temperature range18 - 32 °C
Refrigerating medium weight410 g
Suitable for room volume up to75 m³
Cooling capacity in watts (max)2200 W
Heating capacity in watts (max)- W
Cooling energy efficiency (EER, W/W)2.6
Heating energy efficiency (COP, W/W)-
Current3.7 A
AC input voltage220-240 V
AC input frequency50 Hz
Energy efficiency class (cooling)A
Energy efficiency class (heating)No
Hourly energy consumption (cooling)0.8 kWh
Hourly energy consumption (heating)- kWh
Product colorWhite
Weight and Dimensions IconWeight and Dimensions
Depth690 mm
Width415 mm
Height315 mm
Weight24000 g
Package depth844 mm
Package width462 mm
Package height357 mm
Package weight28000 g