Model 3800
OUTPUT POWER (per channel)
Continuous Average Output Power both channels
driven:
8 ohms, 20 Hz-20 kHz 0.1% THD 375 W
1 kHz 1% THD 440 W
4 ohms, 20 Hz-20 kHz 0.1% THD 600 W
1 kHz 1% THD 750 W
2 ohms, 20 Hz-20 kHz 0.2% THD 850 W
1 kHz 1% THD 1100 W
Bridged Mono operation:
16 ohms, 20 Hz-20 kHz 0.1% THD 720 W
1 kHz 1% THD 880 W
8 ohms, 20 Hz-20 kHz 0.1% THD 1200 W
1 kHz 1% THD 1500 W
4 ohms, 20 Hz-20 kHz 0.2% THD 1700 W
1 kHz 1% THD 2200 W
Distortion: THD – 20 Hz-20 kHz at rated power shall be less than
0.1%. SMPTE-IMD less than 0.025% at rated power.
Frequency Response: 20 Hz-10 kHz ± 0.1 dB
8 Hz-300 kHz +0/-3 dB
Damping Factor: Greater than 200
Dynamic Headroom: 2 dB at 4
Noise: -100 dB 20 Hz-20 kHz
Sensitivity: 1 V RMS for rated power (8 Ω)
Input Impedance: 20 kbalanced or 10 k
unbalanced
Controls:
Front – Flush detented gain control, recessed
AC switch and AC circuit breaker for each
channel.
Rear – Mono-bridging and accessory module
switches.
Indicators: Bi-color LED indicating DC power –
OK/Protect mode, LED clip indicator, -30 dB
and –6 dB signal level indicators, flashing
over-temp indicators.
Cooling: Passive cooling combined with high efficiency
output stage for 50% reduction in dissipated
heat. Unique circuit configuration provides
direct-metal mounting of output devices to
minimize short-term thermal excursions of
power transistors. Fan-assisted cooling
recommended for high duty cycles at 2 ohms.
Amplifier Protection: Indefinite short circuit*, open circuit,
over-temp, ultrasonic and RF protection.
Stable into reactive and mismatched loads.
Inputs protected from overload.
*Output Averaging short circuit protection
(U.S. Pat. 4,321.554)
Load Protection: Individual channel output relays
provide DC Fault, 3 second delayed turn-on
(transient protection), and excessive low-
frequency protection. Instant turn-off, pop
suppression and power interrupt protect is also
provided..
Output Circuit Type: Full complementary two-level high
efficiency.
Output Devices (total): 40
Power Supply: A complete separate power supply for each
channel including AC switch/circuit breaker
and AC cord.
Power Requirements: 120, 220, or 240 Volts, 50 Hz-60 Hz,
13 A (each channel)
Dimensions: Faceplate 19” × 5.25”
Depth (behind mtg,
with rear support) 17.9”
Depth (chassis) 15.9”
Weight: Shipping (lbs.) 75
Net (lbs.) 83

Other manuals for QSC 3800