The
Quad
303 carries no
controls and
may
be
mounted
out of
sight
inside
the
cabinet or at any other
convenient
position
in the installation.
The
Quad
303 may be either
stood on
its
feet
on
a
shelf or base
board of a cabinet,
or
more
securely
fixed
by drilling four holes in
the shelf
or
board to
coincide
with the feet
centres,
removing
the feet
securing screws
and
passing
the longer
screws
provided,
up through these
holes, through
the
feet
which
act
as
spac€rs
to
assist
circulation of air under the
amplifier,
and into
the
tapped
bushes in the base-plate.
Slots or holes
should be cut
in
or
near the base and
in
or
near
the top of any
enclosed compartment to
permit
a flow
of
air upwards
through the
compartment,
past
and through the amplifier
to assist ventilation.
In
confined
spaces
where
the exit vents
are
not
directly
over the amplifier a deflector
plate
of
plywood
or
asbestos
may
be mounted at
an
inclined
angle above the
amplifier to help
guide
the
rising
warm air towards
the
exit vent and
prevent
an accumulation
of warm air
under a
closed
horizontal
top.