Quest DEH 3000 Installation, Operation and Maintenance Instructions
3
www.QuestProtect.com
sales@questprotect.com
quest
quest
MountingHole
MountingHole
24VACYellowWire
24VACRedWire
Damper
WhiteWire
(Optional.See
warningbelow)
Dehumidier
BlueWire
Fan
GreenWire
ON-Detect
Common
OFF-Detect
NormallyOpen
Common
NormallyClosed
Optional
Use
Optional
Use
1. Specications
Part#(P/N) 4027370
Model: QuestDEH3000DigitalControl
Electrical: 24VAC
MaxCurrent–
DMP,COMP,FAN: 1Ampeach
HumidityRange: 10–95%RH,
±
5%
HumidityAccuracy:
±
5%
Output: 3Amps24VAC
Aux.RelayCapacity 5Amps
TempRange/ 30°-90°F,2%
Accuracy
Size 4.95"Lx1.06"Wx4.19"H
FOR HVAC INSTALLER ONLY:
2. Installation
InstalltheQuestDEH3000controlpanelinacentralareaofthe
structurewhereitwillsensetherelativehumidityofthestructure
accurately.Donotinstallthecontrolpanelwhereitmaynot
accuratelysensetherelativehumiditysuchasnearHVACsupply
registers,nearexteriordoorsandwindows,ornearapoolorspa.
Installinaccordancewithallapplicablecodesandstandards.
2.1 Install Instructions
1. Separatethefrontpanelfromthebackpanelbydepressing
themiddlesectionsofthetopandbottomofthefrontpanel.
2. Locatethewiringaccessholeinthe
wallorotheratmountingsurface.
Placethebackpanelintopositionand
drilltheappropriatemountingholes.
3. Insertthescrewsandtighten.Levelas
necessary.
4. Maketheelectricalconnectionstothe
terminalsonthebackpanelasshown
intheapplicablewiringdiagram(see
Sections2.2-2.4).
5. Testtheinstallation(seeSection2.5).
2.2 Wiring
WARNING! DO NOT ALLOW THE YELLOW WIRE FROM THE QUEST DEHUMIDIFIER
TO CONTACT THE RED OR WHITE WIRES FROM THE QUEST DEHUMIDIFIER, DAMAGE TO THE 24-VOLT
TRANSFORMER WILL RESULT.