open the valve to 1 ¼ turn. Allow water to run for 10 15 minutes on new cooling pads to totally saturate them with water.
Once your units cooling pads are saturated then, you are ready to turn on fan and begin to feel the cooling effect from your
new QuietCool. Note: After your cooling pads are broken in (typically takes 1 -2 weeks in operation) it will take less time to
saturate pads for start-up.
5.4 Turn-on Fan
Once your cooling pads are wet you may turn on your QuietCool unit. Now you can begin to feel the QuietCool difference
in temperature. After your QuietCool has run for 5 minutes or so, visually inspect the pads if water is dripping outside the
unit you have too much water, simply turn the water flow valve to the right ½ turn and inspect water flow in another 5
minutes. If there are dry streaks in the cel deck pads open the water flow valve handle ½ turn to increase water check water
flow in another 5 minutes and adjust accordingly. Most QuietCool operations work effectively with valve opened at 1 ¼
turns. This water valve is efficient it requires minimal turning.
6.0 Daily Operating procedures
6.1 Turn-on water pump
Turn on water pump to unit then, turn on fan to low let cooling pads get saturated then turn fan on high for cooling.
Adjust the water flow Your QuietCool operates most efficiently and maintains uniform cooling pad wetness with the
water control valve turned on at 1 ¼ turns. You must determine what works best for you and your specific environment.
6.2 Adjust water flow
Your QuietCool operates most efficiently and maintains uniform cooling pad wetness with the water control valve turned
on at 1 ¼ turns. You must determine what works best for you and your specific environment.
6.2 Turn on fan
When you can see that the cooling pads are saturated with water turn fan on high and feel the cooler air coming from your
QuietCool unit. Adjust the fan speed for your comfort.
6.4 Turn-off unit at end of day
15 minutes before closing for the day turn off water pump with toggle switch leave fan running this action will shut-off
water to the cooling pads while keeping the fan running. The fan will dry out the cooling pads. When the cooling pads are
thoroughly dry turn off fan. Drying your cooling pads thoroughly - everyday will help prevent mold and mildew growth,
plus it will prolong the life of your cooling pads.
7.0 Maintenance
7.1 Access inside of unit
Turn-off water pump and let the fan continue to run until the cooling pads are thoroughly dry (about 10 15 minutes). Once
your cooling pads are completely dry you may turn-off fan. Now unplug electricity to unit to avoid unnecessary shock. Next,
using a 7/16” wrench remove the two retaining bolts from the backside and topside (cooling pad side) of the unit. These