Cod. 2200780113 01 - Edition 10/2014 - 9
17.1 DIGITAL CONTROL ALARMS
N.B. OPERATIONS MARKED  MUST BE CARRIED OUT BY PROFESSIONALLY SKILLED PERSONNEL APPROVED THE
MANUFACTURER
DISPLAY
FLASHING WARNING
NOTES
Possible root causes
Observations
Dryer is working OK
n/a
Warning icon NOT
fashing, label P1 flashing
Fan control probe failed
 replace probe
Warning icon NOT
fashing, label P2 flashing
PDP Temp probe failed
 replace probe
Warning icon NOT
fashing, label H2 flashing
High PDP call for service
 refrigerant leak
 flow rate / inlet
 temperature
exeeding the limit.
Warning icon NOT
fashing, label L2 flashing
Low PDP call for service
 hot gas by pass
valve out of order.
 ambient temperature
lower then limits
EE ALARM
EE alarm is shown when internal EPROM errors happens, if this warning will appear, the dryer will stop running. The error can be reset by pressing
one of the four buttons of the controller, anyway please replace the controller itself.
NOTE: In case of EE alarm please contact your tech support.

Other manuals for Quincy Compressor QPNC 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quincy Compressor QPNC 10 and is the answer not in the manual?

Quincy Compressor QPNC 10 Specifications

General IconGeneral
BrandQuincy Compressor
ModelQPNC 10
CategoryDehumidifier
LanguageEnglish

Related product manuals