Appendix A - Technical Data
122 Quincy Compressor-QSI
®
QSI 245
Full Load Operating Pressure psig 100 110 125 150
75
Less Cabinet °F 120
With Cabinet °F 115
32
50 60
Rotor Diameter mm 204
1775 1785
Female Rotor Speed rpm 1183 1190
Inlet Capacity acfm 246 245 243 241
Displacement at Operating Speed cfm
Aftercooling
352
Aftercooler Approach (standard conditions) °F 3-5
2
O
2
1725
Fan Flow cfm 5500
Water-cooled Cooling
Recommended Inlet Water Pressure psig 40-100
1/9
Aftercooler Approach to Cooling:
Water Temperature °F 13-18
Water Flow less Aftercooler at: 50°F gpm
70°F gpm
90°F gpm
Water Flow with Aftercooler at: 50°F gpm
70°F gpm
90°F gpm 16 28
Compressor Fluid
Total Fluid Capacity gallons 11
Reservoir Fluid Capacity gallons
Fluid Flow gpm 19
Typical Fluid Carryover ppm
Normal Airend Discharge Temperature °F 175-195
Sound (at 1 meter)
Unenclosed (AC/WC) dB(A) 82/80
Standard Cabinet (AC/WC) dB(A) 76/73
Low Sound Cabinet (AC) dB(A) 71