Appendix A - Technical Data
126 Quincy Compressor-QSI
®
QSI 600
Full Load Operating Pressure psig 100 110 125 150
75
Less Cabinet °F 118
With Cabinet °F 110
35
125 150
Rotor Diameter mm 255
1785 1790
Female Rotor Speed rpm 1190 1193
Inlet Capacity acfm 630 623 615 594
Displacement at Operating Speed cfm *data not available*
*data not available*
Aftercooling
Aftercooler Approach (standard conditions) °F 6
2
O
5
1790
Fan Flow cfm 12200
Water-cooled Cooling
Recommended Inlet Water Pressure psig 40-100
1/9
Aftercooler Approach to Cooling:
Water Temperature °F 9-10
Water Flow less Aftercooler at: 50°F gpm *data not available*
70°F gpm 15 16 17 38
90°F gpm 25 27 55 38
Water Flow with Aftercooler at: 50°F gpm *data not available*
70°F gpm 12 14 16 27
90°F gpm 21 24 45 29
Compressor Fluid
Total Fluid Capacity gallons 13
Reservoir Fluid Capacity gallons
Fluid Flow gpm 35
Typical Fluid Carryover ppm 1-3
Normal Airend Discharge Temperature °F 190-195
Sound (at 1 meter)
Unenclosed (AC/WC) dB(A) 87/86
Standard Cabinet (AC/WC) dB(A) 82/81
Low Sound Cabinet (AC) dB(A) *data not available*