INSTALLATION
General
The installation and maintenance of this unit must be carried out in
accordance with the instructions and information given in this Manual, and
must be conducted by designated, qualified and competent personnel.
1. Before commencing, ensure that the installation conditions comply with the
information given in the SPECIFICATION section.
2. Care must be taken during installation to prevent any risk of injury or damage.
3. All electrical connections should be in accordance with BS7671 and undertaken
by a competent person.
4. Isolate mains voltage supply before removing cover.
5. Installations must comply with all current Building and Electrical Regulations in
force, and relevant Guidelines.
6. The installation and usage environment of this product must not be subject to
extremes of moisture or temperature, unauthorised tampering or wilful abuse.
7. All solenoids must be approved to EN 60730-2-8.
Installation
The Rada Pulse Control Box is designed to interface with Rada Pulse sensors and
Rada Pulse solenoid valves (refer to individual Product Manuals for information)
which control the system functions.
The enclosure is intended for wall-mounting to a suitable flat dry surface (fixing screws
are supplied), accessible for maintenance. Make sure that you fit the sealing washers
to the fixing screws before installation.
Note! An installation template is supplied so that the fixing positions can be marked
and drilled without putting the control box on the wall (If the wall is uneven it is
advisable to fit a board to ensure surface is flat and the control box does not become
distorted).
This appliance is intended for permanent connection to the fixed electrical wiring of
the mains electric system via a double pole switched connection unit fused at 3
amps, which has at least 3 mm contact separation.
A mains 230 V supply cable of 2 metre length is pre-connected, this must not be
removed; do not renew the cable inside the box if damaged.
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the rada Pulse and is the answer not in the manual?

rada Pulse Specifications

General IconGeneral
Product TypeElectronic Faucet
Power SupplyBattery
ActivationInfrared Sensor
MaterialBrass
InstallationDeck Mount
Warranty5 years
Water SupplyMixed
Flow Rate3.7 l/min

Related product manuals