EasyManua.ls Logo

RadioLink RC3S - Page 20

RadioLink RC3S
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
Select the setting item "ABP" by pressing “Dec(-)” or “Inc(+)” button,then press
“Enter” key and the initial value of “ABP” will blink. Use “Dec(-)” or “Inc(+)” button
to adjust the return amount.
(Note: In the interface of adjusting the value, return to the initial value"50" by
pressing “Dec(-)” and “Inc(+)” buttons simultaneously for about 1 second.)
Press “Enter” button, the adjusted value stops blinking, now the value has been set.
"0":No return
"50":Return to the 50% position of the brake operation amount
"100":Return to the neutral position.
Brake return amount (ABP)
0 ~ 50 ~ 100
Initial value; 50
- Brake return amount (ABP) is influenced by the "EXP" rate on the brake side.
2. (Delay amount setup)
Select the setting item "DLY" by pressing “Dec(-)” or “Inc(+)” button, then press
“Enter” key and the initial value of “DLY” will blink. Use “Dec(-)”or “Inc(+)” button
to adjust the delay amount.
(Note: In the interface of adjusting the value, return to the initial value "0"by pressing
“Dec(-)” and “Inc(+)” buttons simultaneously for about 1 second.)
Press “Enter” button, the adjusted value stops blinking, now the value has been set.
"0":A.B.S. function performed without any delay
"50":A.B.S function performed after an approximate 0.7 sec delay
"100":A.B.S. function performed after an approximate 1.7 secs delay
Delay amount (DLY)
0 ~ 100
Initial value; 0